CaTiO3 nano ceramic for NTCR thermistor based sensor application
نویسندگان
چکیده
منابع مشابه
Fabrication of PGS/CaTiO3 Nano-Composite for Biomedical Application
Biodegradable elastomeric materials are gaining extensive attention in the field of soft tissue engineering. Poly (glycerol sebacate) (PGS) is a novel biocompatible elastomer in this scope. However this polymer has poor mechanical properties especially when the molar ratio of glycerol is higher than sebacic acid. Calcium Titanate (CaTiO3) is a biocompatible ceramic with some degr...
متن کاملapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولThermistor-based breathing sensor for circadian rhythm evaluation.
One of the most frequently used methods to sense breathing pattern is to detect airflow using a nasal thermistor or a thermocouple sensor. Prolonged, minimally intrusive measurement of the breathing pattern is particularly important for polysomnography, sleeping disorders, stress monitoring, biofeedback techniques, and circadian rhythm analysis. Although most applications require only breathing...
متن کاملTiO2 based surface acoustic wave gas sensor with modified electrode dimensions for enhanced H2 sensing application
The design and optimization of nanostructure-based surface acoustic wave (SAW) gas sensor is analyzed based on TiO2 sensing layer and modified electrode dimensions. The sensitivity of the gas sensor depends upon the type of sensing layer used and active surface area obtained by varying the aspect ratio. The performance of the sensor is observed from 0.1ppm to 100ppm concentration of ...
متن کاملMicro-PCR Chip NTC-Thermistor Sensor-Calibration System
In this paper, we implement a Steinhart-Hart calibration-factor value measurement system to obtain accurate temperature measurements of a negative-temperature coefficient thermistor. The thermistor is mounted on a micro-polymerase chain reaction (PCR) chip in a micro-PCR systemthat requires accurate temperature measurement and control. When obtaining the calibration-factor value, it is impossib...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Advanced Ceramics
سال: 2014
ISSN: 2226-4108,2227-8508
DOI: 10.1007/s40145-014-0100-6