Cathodic Current of Steel Structures with Seawater Resistant Stainless Steel and Estimation of Weight Loss of Sacrificial Anode
نویسندگان
چکیده
منابع مشابه
non-linear study of various slit shear walls in steel structures
seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...
15 صفحه اولStainless steel structures in fire
The initial material cost of structural stainless steel is about four times that of structural carbon steel, due largely to the expense of the alloying elements and the relatively low volume of production. Given broadly similar structural performance, additional areas of benefit need to be identified and exploited in order to establish stainless steel as a viable alternative material for constr...
متن کاملSunlight-enhanced calcareous deposition on cathodic stainless steel in natural seawater.
In replicate series of experiments in natural seawater, one in full darkness and the other in a 1:1 diurnal cycle with as little as ~5% of natural solar illumination, sunlight promoted calcareous deposition on cathodic stainless steel surfaces. As exemplified by scanning electron microscopy, the deposit that formed under the natural diurnal cycle, in the presence of photosynthetic biofilms, was...
متن کاملCompressibility of 304 Stainless Steel Powder Metallurgy Materials Reinforced with 304 Short Stainless Steel Fibers
Powder metallurgy (P/M) technique is usually used for manufacturing porous metal materials. However, some P/M materials are limitedly used in engineering for their performance deficiency. A novel 304 stainless steel P/M material was produced by a solid-state sintering of 304 stainless steel powders and 304 short stainless steel fibers, which were alternately laid in layers according to mass rat...
متن کاملAnalysis of Stray Current Induced by Cathodic Protection on Steel- Framed Masonry Structures
Cathodic protection (CP) has been successfully employed to protect steel-framed masonry buildings from corrosion related damage. When a CP system is installed to protect the structural members, other metallic items which are within the fabric of the structure but are not in direct electrical continuity may suffer from stray current interactions, resulting in accelerated corrosion of the discont...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Society of Materials Science, Japan
سال: 2010
ISSN: 1880-7488,0514-5163
DOI: 10.2472/jsms.59.137