Cathode-Ray Tube using Tunnel Cathode

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Channel Multiplier Cathode-ray Tube

This paper describes a new approach to cathode-ray tube design aimed at achieving a significant depth reduction. The addressing function of the electron beam has been separated from the light generation process by a channel electron multiplier array, allowing the use of a novel deflection system based on a low-power scanning beam. Monochrome versions of the thin tube have been made with a 12" (...

متن کامل

Luminance artifacts of cathode-ray tube displays for vision research.

Phosphor persistence, video bandwidth, DC restoration and high-voltage regulation affect the appearance of images presented on cathode-ray tubes (CRTs), potentially resulting in differences between nominal and actual stimuli. We illustrate these effects by measuring physical parameters of horizontal and vertical static and counter-phase flickering gratings, and we illustrate problems for vision...

متن کامل

Visual Evoked Potential Using Head-Mounted Display Versus Cathode Ray Tube: A Pilot Study

OBJECTIVE To present a new stimulation method based on the use of a head-mounted display (HMD) during pattern reversal visual evoked potential (PR-VEP) testing and to compare variables of HMD to those of conventional cathode ray tube (CRT). METHODS Twenty-three normal subjects without visual problems were recruited. PR-VEPs were generated using CRT or HMD stimuli. VEP outcome measures include...

متن کامل

X-ray Emission Accompanying Cathode Microdischarge

Electrical discharge in vacuum is accompanied by X-ray radiation. Knowledge of the generation mechanism of radiation may lead to its practical use. The analysis of this phenomenon indicates that it is only at the discharge development phase until the moment of the anode plasma generation that the proper conditions for X-ray generation are satisfied. The intensity of radiation is dependent on th...

متن کامل

A multi-channel cathode-ray phonocardiograph.

The difficulties of recording the faint murmurs of early rheumatic valvulitis are well known, and for this reason it was considered advisable to develop a cathode-ray phonocardiograph. This is theoretically the ideal recording device owing to its minimal inertia and high sensitivity. This phonocardiograph is intended to provide objective confirmation of clinical findings on auscultation, record...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of the Institute of Television Engineers of Japan

سال: 1968

ISSN: 1884-9644

DOI: 10.3169/itej1954.22.653