Cathode-ray Luminescence Caused by Frictional Static Electricity

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Static electricity and rotameters.

Inaccuracies in Rotameters, caused by static charges, seem to be relatively common. Inaccuracies can be of a very serious order. Charges outside the tubes can be removed easily by antistatic spray. Charges inside the tube are very difficult to remove except by dismantling the apparatus or by the use of a radioactive pistol. Charges have been measured and are much larger than had been supposed a...

متن کامل

The Channel Multiplier Cathode-ray Tube

This paper describes a new approach to cathode-ray tube design aimed at achieving a significant depth reduction. The addressing function of the electron beam has been separated from the light generation process by a channel electron multiplier array, allowing the use of a novel deflection system based on a low-power scanning beam. Monochrome versions of the thin tube have been made with a 12" (...

متن کامل

X-ray Emission Accompanying Cathode Microdischarge

Electrical discharge in vacuum is accompanied by X-ray radiation. Knowledge of the generation mechanism of radiation may lead to its practical use. The analysis of this phenomenon indicates that it is only at the discharge development phase until the moment of the anode plasma generation that the proper conditions for X-ray generation are satisfied. The intensity of radiation is dependent on th...

متن کامل

Computing Static Electricity on Human Hair

We present a framework to study electrical charge phenomena on human hair. We propose a fiber based hair model which bases on the special theory of Cosserat Rods to overcome the well known difficulties one has to deal with when simple particle systems are used. We show how such models can efficiently be employed in conjunction with the fast multipole method to account for Coulomb far-field inte...

متن کامل

A multi-channel cathode-ray phonocardiograph.

The difficulties of recording the faint murmurs of early rheumatic valvulitis are well known, and for this reason it was considered advisable to develop a cathode-ray phonocardiograph. This is theoretically the ideal recording device owing to its minimal inertia and high sensitivity. This phonocardiograph is intended to provide objective confirmation of clinical findings on auscultation, record...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Vacuum Society of Japan

سال: 2013

ISSN: 1882-2398,1882-4749

DOI: 10.3131/jvsj2.56.179