Casting Shrinkage of ZAC #1, Silmin(13%Si), AZ91 and Pure Zn
نویسندگان
چکیده
منابع مشابه
In vitro corrosion of pure magnesium and AZ91 alloy—the influence of thin electrolyte layer thickness
In vivo degradation predication faces a huge challenge via in vitro corrosion test due to the difficulty for mimicking the complicated microenvironment with various influencing factors. A thin electrolyte layer (TEL) cell for in vitro corrosion of pure magnesium and AZ91 alloy was presented to stimulate the in vivo corrosion in the micro-environment built by the interface of the implant and its...
متن کاملAlloy Shrinkage Factors for the Investment Casting Process
This study deals with the experimental measurements and numerical predictions of alloy shrinkage factors (SFs) related to the investment casting process. The dimensions of the A356 aluminum alloy casting were determined from the numerical simulation results of solidification, heat transfer, fluid dynamics, and deformation phenomena. The investment casting process was carried out using wax patte...
متن کاملDesign & Analysis of Pure Iron Casting with Different Moulds
In the present work it has been shown that FEA software like ANSYS may play an important role in predicting cast defect before the actual casting. Transient thermal analysis and Couple-Field analysis in ANSYS can predict temperature distribution and thermal stress distribution in the casting after solidification very accurately. This fact has been proved by validating a transient thermal analys...
متن کاملan inverstigation into the shrinkage behavior (kinetics) of microfilled hybrid and nano dental composites
چکیده ندارد.
15 صفحه اولComparative study of two commercially pure titanium casting methods
UNLABELLED The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Japan Institute of Metals and Materials
سال: 1965
ISSN: 0021-4876,1880-6880
DOI: 10.2320/jinstmet1952.29.1_105