Carrying capacity of reinforced concrete columns, reinforced with collars from fiber-reinforced plastics, with little dynamic loads
نویسندگان
چکیده
The article presents the results of experimental studies carrier ability, longitudinal and transverse deformations reinforced concrete columns, clips made fiber-reinforced plastics, with a few repeated loads. Dependences residual strength after cyclic compressive forces are obtained. Are given suggestions for acceptable deformation values as well proposals calculation design.
منابع مشابه
Axial Compressive Strength of Reinforced Concrete Columns Wrapped with Fiber Reinforced Polymers (FRP)
This paper presents the results of a study on the axial compressive strength of columnsstrengthened with FRP wrap. The experimental part of the study included testing 6 reinforcedconcrete columns in two series. The first series comprised three similar circular reinforced concretecolumns strengthened with FRP wrap. The second series consisted of three similar square columns,two with sharp corner...
متن کاملRehabilitation of Reinforced Concrete Columns
In recent years, rehabilitation has been the subject of extensive research due to increased spending on building work and repair of built works. In all cases, it is absolutely essential to carry out methods of strengthening or repair of structural elements, and that following an inspection analysis and methodology of a correct diagnosis. The reinforced concrete columns are important elements in...
متن کاملRetrofitting of Reinforced Concrete Beams with Steel Fiber Reinforced Composite Jackets
In the present study, a new method for retrofitting reinforced concrete beam is introduced in which steel-concrete composite jackets containing steel fiber is used. For this purpose, 75% of the peripheral surface of reinforced concrete beams was initially reinforced using steel plates and bolts, and steel fiber reinforced concrete was used between the steel plates and the peripheral surfaces of...
متن کاملSeismic Response of Reinforced Concrete Columns
There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...
متن کاملFragility Curves for Reinforced Concrete Frames with Lap-Spliced Columns
Placing column lap-splice in the locations of possible nonlinear deformation may adversely affect the structures response to strong ground motions. Localization of damage in splice zone may change the structural response and prevent the load redistribution and development of a uniform pattern of nonlinear excursions among the various members. Validated by existing laboratory experiments, this s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2023
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202337103060