Cardiovascular responses to endotracheal intubation with the Bullard and the Macintosh laryngoscopes
نویسندگان
چکیده
منابع مشابه
Endotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes.
BACKGROUND The Airtraq laryngoscope (Prodol Ltd., Vizcaya, Spain) is a novel single-use tracheal intubation device. The authors compared ease of intubation with the Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization in a randomized, controlled clinical trial. METHODS Forty consenting patients presenting for surgery requiring tracheal intubation were randomly as...
متن کاملComparison of the Macintosh and Airtraq Laryngoscopes in Endotracheal Intubation Success.
OBJECTIVE Endotracheal intubation of patients is an effective method for controlling airway and breathing. However, laryngoscopy and endotracheal intubation is not easy in every case. There is a recent abundance of equipment used for controlling ventilation and intubation. Airtraq is one of those equipments. In this study, our main objective is to compare the success rates of the Airtraq and Ma...
متن کاملEvaluation of the Hemodynamic Response to Endotracheal Intubation Comparing the Airtraq® with Macintosh Laryngoscopes in Cardiac Surgical Patients
INTRODUCTION Cardiac patients are more prone to develop hemodynamic instability on induction of anesthesia and endotracheal intubation. The Airtraq(®) optical laryngoscope is a single-use rigid video laryngoscope that has been developed to facilitate tracheal intubation. There are limited studies comparing differences in the circulatory responses to Airtraq(®) and direct Macintosh larynngoscopy...
متن کاملCervical spine movement during laryngoscopy with the Bullard, Macintosh, and Miller laryngoscopes.
BACKGROUND Direct laryngoscopy requires movement of the head, neck, and cervical spine. Spine movement may be limited for anatomic reasons or because of cervical spine injury. The Bullard laryngoscope, a rigid fiberoptic laryngoscope, may cause less neck flexion and head extension than conventional laryngoscopes. The purpose of this study was to compare head extension (measured externally), cer...
متن کاملIntubation biomechanics: laryngoscope force and cervical spine motion during intubation with Macintosh and Airtraq laryngoscopes.
INTRODUCTION Laryngoscopy and endotracheal intubation in the presence of cervical spine instability may put patients at risk of cervical cord injury. Nevertheless, the biomechanics of intubation (cervical spine motion as a function of applied force) have not been characterized. This study characterized and compared the relationship between laryngoscope force and cervical spine motion using two ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Journal of Anesthesia/Journal canadien d'anesthésie
سال: 2002
ISSN: 0832-610X,1496-8975
DOI: 10.1007/bf03017938