Cardiac Rhythm Management Device Infections
نویسندگان
چکیده
منابع مشابه
Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003.
To the Editor: Clinical indications for cardiac rhythm management devices (CRMDs) have expanded dramatically. The impact of this expansion upon rates of CRMD infection, a complication of device therapy that often requires system explantation (1), has not been clearly defined. We hypothesized that the current growth in implantable cardioverter defibrillator (ICD) utilization would impact rates o...
متن کاملCardiac device infections: definition, classification, differential diagnosis, and management.
Cardiac device infections (CDIs) continue to be a serious clinical problem, with varying terminology and different classifications constituting one of the major diagnostic and therapeutic challenges in routine clinical practice. The problem invariably arises during an attempt to estimate the extent of the infection, which in consequence determines the choice of treatment strategy (duration of a...
متن کاملManagement of Cardiac Electronic Device Infections: Challenges and Outcomes.
Cardiac implantable electronic device (CIED) infection is an increasing problem. Reasons for this are uncertain, but likely relate to an increasing proportion of implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy (CRT) devices implanted, as well as implantations in 'higher risk' candidates, i.e. patients with heart failure, diabetes and renal failure. Challenges ...
متن کاملCardiac implantable electronic device infections: presentation, management, and patient outcomes.
BACKGROUND Indications for cardiac implantable electronic devices (CIEDs) are increasing. Although CIED infections occur infrequently, the impact of this outcome is expected to be substantial. OBJECTIVE The purpose of this study was to the evaluate the outcome of patients undergoing removal of infected CIEDs. METHODS A retrospective study was conducted of all patients with proven or suspect...
متن کاملCardiac electrical device-related bacterial infections: Prevention, diagnosis, and management
Significant developmentin modern cardiac (or cardiovascular) electrical devices (CIEDs), including permanent pacemakers, implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy, is contributing to the improvement in both the survival rate and quality of life in patients with cardiac arrhythmias and/or heart failure. The number of CIED implantations has increased si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Infection and Chemotherapy
سال: 2011
ISSN: 2093-2340
DOI: 10.3947/ic.2011.43.3.234