Cardiac Resynchronization Therapy-Defibrillator Pocket Infection Due to Non-Typhoidal Salmonella Infection

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardiac defibrillator pocket infection due to a previously undescribed Cupriavidus species.

The genus Cupriavidus consists of Gram-negative, nonfermenting bacteria most of which are environmental organisms, though some species have been associated with human disease. We report the recovery and identification of an isolate that represents a previously undescribed species of Cupriavidus from an implantable cardiac defibrillator pocket infection.

متن کامل

Increased late complex device infections are determined by cardiac resynchronization therapy-defibrillator infection.

AIMS The incidence of cardiac device infection (CDI) more than 12 months following complex device implant (late infection) has not been extensively reported. Our objective was to compare both early (within 12 months) and late infection rates following complex device implantation. METHODS AND RESULTS Patients who received either a cardiac resynchronization therapy (CRT) device with or without ...

متن کامل

Automatic implantable cardioverter defibrillator pocket infection due to Providencia rettgeri: a case report

Coagulase-negative staphylococci and Staphylococcus aureus are the commonest pathogens involved in infections of pacemaker-defibrillator systems. Among causative Gram-negative bacteria, infections due to Klebsiella, Serratia, Pseudomonas, Acinetobacter and other species have been reported. We report herein a unique case of an automatic implantable cardioverter defibrillator infection due to Pro...

متن کامل

Inappropriate Shock Delivered By Implantable Cardioverter Defibrillator - Cardiac Resynchronization Therapy (ICD-CRT) Due To Myopotential Oversensing

The clinical efficacy of ICD-CRT therapy depends on accurate sensing of intracardiac signals and sensing algorithms. We report the occurrence of sensing abnormality in a patient with ICD-CRT. In this patient, oversensing of myopotentials during strenuous muscular activity resulted in an inappropriate ICD-CRT discharge. Although modern ICDs are highly effective in detecting and terminating malig...

متن کامل

Predictors of response to cardiac resynchronization therapy in the Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT).

BACKGROUND We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device. METHODS AND RESULTS The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchroni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Korean Journal of Medicine

سال: 2013

ISSN: 1738-9364

DOI: 10.3904/kjm.2013.84.3.418