CARDIAC RESYNCHRONISATION THERAPY EFFECTS COMPARE OF THE SURGERY EPICARDIAL LEAD VERSUS CORONARY SINUS LEAD PLACEMENT

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing.

OBJECTIVE Biventricular pacing has demonstrated improvement in cardiac function in treating congestive heart failure (CHF). Two different operative strategies (coronary sinus vs. epicardial stimulation) for left ventricular (LV) pacing were compared. METHODS Since April 1999, a total of 86 patients (pts, age: 63+/-10 years) with depressed systolic LV function (mean ejection fraction 24+/-9%),...

متن کامل

Surgical placement of left ventricular lead for cardiac resynchronisation therapy after failure of percutaneous attempt

OBJECTIVE Cardiac resynchronisation therapy has been shown to be an effective treatment to improve functional status and prolong survival of patients in advanced chronic heart failure. This study assessed the surgical outcomes of left anterior mini-thoracotomy for the implantation of left ventricular epicardial pacing leads in cardiac resynchronisation therapy. METHODS Our study consisted of ...

متن کامل

Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations

A 45-year-old woman with dilated cardiomyopathy was admitted for the upgrade of a previously implanted pacemaker. Echocardiography showed intraventricular dyssynchrony and a low ejection fraction (0.35). Treatment with a cardiac resynchronization therapy defibrillator (CRT-D) was selected and the device was implanted. CRT-D interrogation revealed proper function. Following procedure termination...

متن کامل

Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even th...

متن کامل

Balloon Venoplasty of Subclavian Vein and Brachiocephalic Junction to Enable Left Ventricular Lead Placement for Cardiac Resynchronisation Therapy

This report describes the successful implantation of a LV lead using balloon venoplasty to overcome a very tight stenosis of the right subclavian vein / brachiocephalic junction for cardiac resynchronisation therapy (CRT-P) in a patient with a right sided CRT-P system and a failed epicardial LV lead. It is important for device implanters to be familiar with interventional equipments and techniq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Heart

سال: 2012

ISSN: 1355-6037,1468-201X

DOI: 10.1136/heartjnl-2012-302920n.26