Cardiac Perfusion and Innervation Assessment by CZT-SPECT: Have a Look to Simultaneous Dual-isotope Protocol

نویسندگان

چکیده

Abstract Purpose of Review The purpose this review is to provide a summary on the status art simultaneous perfusion-innervation imaging by CZT-SPECT and clarify its potential applications in clinical practice. Recent Findings Introduction CZT cameras represented critical breakthrough nuclear cardiology. Although it has been demonstrated that cardiac innervation may be easily assessed CZT-SPECT, as for now, there are only few studies investigating perfusion with dual-isotope cameras. Summary Perfusion assessment camera feasible tool, allowing reduce radiation dose exposure acquisition time, thanks better spatial, temporal, energy resolution, higher compliance patients. Moreover, technique allows integrate regional evaluation myocardial perfusion/innervation status, providing more accurate information risk stratification different disease.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease.

UNLABELLED A triple-detector, multipinhole SPECT system was optimally configured to perform simultaneous (201)Tl (stress)/(99m)Tc (rest) myocardial perfusion imaging (MPI) using a protocol that permitted direct diagnostic comparison of this multipinhole SPECT system with conventional rotational SPECT. METHODS Both the rotational and the multipinhole SPECT systems used the same model gamma-det...

متن کامل

Dual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector.

Objective(s): The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the ef...

متن کامل

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Simultaneous Dual-Isotope SPECT Imaging for the Detection and Characterization of Parathyroid Pathology

V a r i o u s imaging methods have been used for the preoperative localization of parathyroid tumors in patients with hyperparathyroidism. Among the noninvasive methods, several scintigraphic techniques have been employed, including variations on the dual-isotope 2°ITI/99mTC subtraction techniques (1-3). Modification of this technique, using 123I instead of [99mTC] pertechnetate, has also been ...

متن کامل

Simultaneous dual-isotope SPECT imaging for the detection and characterization of parathyroid pathology.

A technique is described involving simultaneous, dual-isotope SPECT imaging. Using 123I and 201TI, a patient study is presented, demonstrating the clinical utility of this technique in the detection and characterization of parathyroid pathology. The use of this technique in other clinical situations is discussed.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Current Cardiovascular Imaging Reports

سال: 2023

ISSN: ['1941-9066', '1941-9074']

DOI: https://doi.org/10.1007/s12410-023-09578-0