Cardiac C-Arm CT: A Unified Framework for Motion Estimation and Dynamic CT

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diaphragm Tracking for Respiratory Motion Compensated Cardiac C-Arm CT

Long acquisition times of several seconds lead to image artifacts in cardiac C-arm CT. While ECG gating is able to select a certain heart phase, residual artifacts are mostly caused by respiratory motion. In order to improve image quality, it is important to accurately estimate the breathing motion that occurred during image acquisition. It has been shown that diaphragmmotion is correlated to t...

متن کامل

Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT.

The acquisition of data for cardiac imaging using a C-arm computed tomography system requires several seconds and multiple heartbeats. Hence, incorporation of motion correction in the reconstruction step may improve the resulting image quality. Cardiac motion can be estimated by deformable three-dimensional (3D)/3D registration performed on initial 3D images of different heart phases. This moti...

متن کامل

Cardiac C-Arm CT: Image-based Gating

Image guidance during cardiac interventional procedures (IP) using cardiac C-arm CT systems is desirable for many procedures. Applying the concept of retrospective electrocardiogram gating (ECG) to the acquisition of multiple, ECG-triggered rotational acquisitions using a C-arm system allows the 3D+t reconstruction of the heart. The process of retrospective gating is a crucial component of 3-D ...

متن کامل

Respiratory Motion Compensation for C-Arm CT Liver Imaging

In C-arm CT 3-D liver imaging, breathing leads to motion artifacts due to the relatively long acquisition time. Often, even with breath-holding residual respiratory motion can be observed. These artifacts manifest in blurring and interfere clinical investigations such as liver tissue imaging. For 3-D medical image reconstruction a respiratory motion estimation and compensation is required. In t...

متن کامل

Coping with real world data: Artifact reduction and denoising for motion-compensated cardiac C-arm CT.

PURPOSE Detailed analysis of cardiac motion would be helpful for supporting clinical workflow in the interventional suite. With an angiographic C-arm system, multiple heart phases can be reconstructed using electrocardiogram gating. However, the resulting angular undersampling is highly detrimental to the quality of the reconstructed images, especially in nonideal intraprocedural imaging condit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Medical Imaging

سال: 2009

ISSN: 0278-0062,1558-254X

DOI: 10.1109/tmi.2009.2025499