Carbon dioxide absorption and desorption properties of Ba<sub>3</sub>Al<sub>2</sub>O<sub>6</sub>
نویسندگان
چکیده
منابع مشابه
investigation of the electronic properties of carbon and iii-v nanotubes
boron nitride semiconducting zigzag swcnt, $b_{cb}$$n_{cn}$$c_{1-cb-cn}$, as a potential candidate for making nanoelectronic devices was examined. in contrast to the previous dft calculations, wherein just one boron and nitrogen doping configuration have been considered, here for the average over all possible configurations, density of states (dos) was calculated in terms of boron and nitrogen ...
15 صفحه اولExperimental Investigation of Reactive Absorption of Ammonia and Carbon Dioxide by Carbonated Ammonia Solution
In this work, reactive absorption of gases in aqueous electrolyte solutions has been investigated resulting in the development of a procedure in order to calculate the concentrations of ionic and molecular species in the liquid phase. Two duplicate experiments were conducted to investigate simultaneous reactive absorption of ammonia and carbon dioxide in partially carbonated ammonia solutio...
متن کاملAbsorption of Carbon dioxide in Packed Column
The absorption of carbon dioxide into aqueous ammonia solution using packed column was investigated. The volumetric overall mass transfer coefficients (KGav) for CO2 absorption into aqueous ammonia solutions were evaluated over ranges of main operating variables , that is, upto 16kPa partial pressure of CO2, 61-214 m 3 /(m 2 .h) gas flow rate, 0.753.06 m 3 /(m 2 .h) liquid flow rate, 2%16% ammo...
متن کاملModeling and Experimental Study of Carbon Dioxide Absorption in a Flat Sheet Membrane Contactor
comIn the present study, CO2 removal from natural gas stream has been studied using a flat sheet membrane contactor. A three dimensional mathematical model is developed to describe the process. The model considers the transport of a gas mixture containing carbon dioxide and methane through a flat sheet membrane contactor module. The model is based on the non-wetted mode of operation, in which t...
متن کاملIi. the Carbon Dioxide Absorption Curve and Carbon Dioxide Tension of the Blood in Cardiac Dyspnea
In cardiac dyspnea the carbon dioxide tension of the alveolar air as determined by the Haldane method is lower than normal in comparison with the plasma bicarbonate as measured by means of the Van Slyke pipette (1, 2). The ratio between these two in health and in most pathological conditions has been shown by Van Slyke, Stillman, and Cullen (3), Walker and Frothingham (4), and Peters (1, 5) to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Ceramic Society of Japan
سال: 2016
ISSN: 1348-6535,1882-0743
DOI: 10.2109/jcersj2.15225