Capitolunate Arthrodesis versus Four-corner Arthrodesis in Scaphoin Nonunion Advanced Collapsed Wrist Treatment

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four-corner Arthrodesis

Although nearly every combination of intercarpal arthrodeses has been described, excision of the scaphoid and fusion of the remaining carpal bones in neutral alignment was a unique concept when it was introduced nearly 20 years ago. This time-tested and established procedure that is commonly known as the 4-corner or 4-bone arthrodesis is based on the principle that the radiolunate articulation ...

متن کامل

Outcome of four-corner arthrodesis for advanced carpal collapse: circular plate versus traditional techniques.

Twenty eight patients with advanced carpal collapse (20 with scapho-lunate advanced collapse [SLAC] and 8 with scaphoid-nonunion advanced collapse [SNAC]) who were treated with a four-corner arthrodesis were reviewed; 23 had a good or excellent outcome. The mean DASH score was 41. The flexion/extension arc decreased from 72 degrees to 52 degrees. Gripping force increased from 46% to 72%. The ra...

متن کامل

arthropathy: A systematic review Clinical outcomes of proximal row carpectomy versus four-corner arthrodesis for post-traumatic wrist

We conducted a systematic review of studies reporting clinical outcomes after proximal row carpectomy or to four-corner arthrodesis for scaphoid non-union advanced collapse or scapholunate advanced collapse arthritis. Seven studies (Levels I–III; 240 patients, 242 wrists) were evaluated. Significantly different postoperative values were as follows for four-corner arthrodesis versus proximal row...

متن کامل

Four-corner arthrodesis using the Quad memory staple.

Range of motion, pain, consolidation and complications were evaluated for nine patients who underwent four-corner arthrodesis using the Quad Memory Staple (QMS) at a mean follow-up of 44 months. The mean pre-operative range of motion was 50 degrees extension, 62 degrees flexion, 9 degrees radial deviation and 24 degrees ulnar deviation. The postoperative range of motion was similar to previous ...

متن کامل

Four-corner arthrodesis using two headless compression screws.

We present the outcome of four-corner wrist arthrodesis using two headless compression screws for fixation. The study group consisted of 27 patients who underwent arthrodesis from 1998 through 2007. Data on demographic parameters, diagnosis, range of motion, pain and complications were collected from the medical files. A total of 77 series of anteroposterior, oblique, and lateral x-rays were re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Revista Iberoamericana de Cirugía de la Mano

سال: 2019

ISSN: 1698-8396,1698-840X

DOI: 10.1055/s-0039-1688971