Capillary isoelectric focusing after sample enrichment with immunoaffinity chromatography in a single capillary

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary isoelectric focusing after sample enrichment with immunoaffinity chromatography in a single capillary

For accurate micro-scale quantification of a specific protein in biological fluids, immunoaffinity chromatography (IAC) and isoelectric focusing (IEF) were combined in a single fused-silica capillary. The inner wall of the capillary was coated with an anti-E-tag antibody at the inlet side to form an IAC column, and polydimethylacrylamide, a neutral polymer, at the outlet side to form the capill...

متن کامل

Capillary Isoelectric Focusing

Beale SC (1998) Capillary electrophoresis. Analytical Chemistry 70: 279. (This journal prints every two years a review on capillary electrophoresis. The article is written by an expert in the Reld and covers more or less all developments in CE including CGE of the preceding years.) Grossmann PD and Colburn JC (eds) (1996) Capillary Electrophoresis: Theory and Practice. San Diego: Academic Press...

متن کامل

Isoelectric focusing sample injection for capillary zone electrophoresis in a fused silica capillary.

An improvement has been made to couple isoelectric focusing (IEF) sample injection and capillary zone electrophoresis in an untreated fused silica capillary. Electroosmotic flow is efficiently prevented by simply using a rubber block at the outlet end of the capillary during IEF sample injection. The experimental conditions that affect the concentration effect are discussed. A concentration enh...

متن کامل

Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection.

CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo...

متن کامل

Immunoaffinity screening with capillary electrochromatography.

Highly efficient capillary electrochromatographic separations of cardiac glycosides and other steroids are presented. Employing butyl-derivatized silica particles as stationary phase resulted in a nearly three times faster electroosmotic flow (EOF) compared to capillary electrochromatography (CEC) with octadecyl silica particles. On-column focusing with a preconcentration factor of 180 was perf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Scientific Reports

سال: 2016

ISSN: 2045-2322

DOI: 10.1038/srep39221