Capillary gap flow cell as capillary-end electrochemical detector in flow-based analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal end effects on electroosmotic flow in a capillary

Thermal end effects on electroosmotic flow in a capillary are numerically investigated in this paper. The model accounts for the dynamic coupling effects of Joule heating on the temperature field, the electrical double layer field, the applied electric potential field and the flow field in the full capillary from reservoir to reservoir. These fields are strongly coupled via temperature dependen...

متن کامل

Viscoelastic potential flow analysis of capillary instability

Analysis of the linear theory of capillary instability of threads of Maxwell fluids of diameter D is carried out for the unapproximated normal mode solution and for a solution based on viscoelastic potential flow. The analysis here extends the analysis of viscous potential flow [Int. J. Multiphase Flow 28 (2002) 1459] to viscoelastic fluids of Maxwell type. The analysis is framed in dimensionle...

متن کامل

Viscous Potential Flow Analysis of Capillary Instability

Capillary instability of a viscous fluid cylinder of diameter D surrounded by another fluid is determined by a Reynolds number J = V D `= `, a viscosity ratio m = a= ` and a density ratio ` = a= `. Here V = = ` is the capillary collapse velocity based on the more viscous liquid which may be inside or outside the fluid cylinder. Results of linearized analysis based on potential flow of a viscous...

متن کامل

Arteriolar control of capillary cell flow in striated muscle.

This study tests the hypothesis that capillary perfusion is controlled in groups rather than at the level of the individual capillary. We measured cell flux (using cells labeled with substituted tetramethyl rhodamine isothiocyanate, XRITC) and vessel diameter in adjoining arterioles of the terminal vasculature of hamster cremaster muscle (Nembutal, 70 mg/kg i.p.) during rest and hyperemia (10(-...

متن کامل

Light-governed capillary flow in microfluidic systems.

Light-based flow systems for point-of-care devices are of interest because, in principle, sunlight could be used to operate them, potentially allowing for high functionality with minimal device complexity and expense. A light-operated method to drive flow using poly(N-isopropylacrylamide), a 'smart' polymer that changes wettability as a function of temperature, is introduced. It is grafted onto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Electrochimica Acta

سال: 2019

ISSN: 0013-4686

DOI: 10.1016/j.electacta.2019.02.026