Can optic nerve sheath diameter assess increased intracranial pressure in pneumoperitoneum and trendelenburg position?
نویسندگان
چکیده
منابع مشابه
Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position
BACKGROUND It remains to be elucidated whether the Trendelenburg position increases intracranial pressure (ICP). ICP can be evaluated by measuring the sonographic optic nerve sheath diameter (ONSD). We investigated the effect of the isolated Trendelenburg position on ONSD in patients undergoing robot-assisted laparoscopic radical prostatectomy. Additionally, we evaluated the effect of the Trend...
متن کاملEffect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
BACKGROUND Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelen...
متن کاملAuthor's response to reviews Title:Sonographic Optic Nerve Sheath Diameter as a Surrogate Measure for Intracranial Pressure in Anesthetized Patients in the Trendelenburg Position Authors:
متن کامل
sonographic optic nerve sheath diameter as a screening tool for detection of elevated intracranial pressure
introduction: timely diagnosis and treatment of post traumatic, elevated intracranial pressure (eicp), could reduce morbidity and mortality, as well as improve patients’ outcome. this study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (onsd) in detection of eicp. methods: sonographic onsd of patients with head trauma or cerebrovascular accident suspic...
متن کاملSonography for determining the optic nerve sheath diameter with increasing intracranial pressure in a porcine model.
OBJECTIVES This study investigated whether it is feasible to use sonography to monitor changes in the optic nerve sheath diameter in a porcine model. METHODS A fiber-optic intracranial pressure transducer was surgically placed through the frontal sinus directly into the brain parenchyma of adult Yorkshire pigs (n = 5). A second bolt was placed on the contralateral side for intraparenchymal fl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Egyptian Journal of Anaesthesia
سال: 2019
ISSN: 1110-1849
DOI: 10.1080/11101849.2019.1678296