Can LC and LC-MS ever replace immunoassays?
نویسندگان
چکیده
منابع مشابه
Lc-ms Instrument Calibration
As analytical and bioanalytical methods must be validated before using them for routine sample analysis and after changing method parameters (see Chapter 8), instruments such as liquid chromatography coupled with mass spectrometry (LCMS) or tandem mass spectrometry (LC-MS/MS), which are utilized to perform the analysis, should be calibrated and qualified. In addition, an instrument’s performanc...
متن کاملMiniaturization in LC – MS
2 Introduction In the April edition of this magazine1 Ron Majors, in his annual report on new columns and accessories from the Pittsburgh conference, reported how at the 2002 conference the largest number of product introductions were for biomolecule separations and for liquid chromatography–mass spectrometry (LC–MS). He went on to state that speciality HPLC columns for chiral compounds, biomol...
متن کاملLC-MS and LC-MS/MS studies of incorporation of 34SO3 into glycosaminoglycan chains by sulfotransferases.
The specificities of glycosaminoglycan (GAG) modification enzymes, particularly sulfotransferases, and the locations and concentrations of these enzymes in the Golgi apparatus give rise to the mature GAG polysaccharides that bind protein ligands. We studied the substrate specificities of sulfotransferases with a stable isotopically labeled donor substrate, 3'-phosphoadenosine-5'-phosphosulfate....
متن کاملLC-ESI-MS/MS Alkaloidal Profiling and Biological Investigation of Cleistocactus winteri Stems
Cleistocactus winteri is a succulent plant of the Cactaceae family, commonly known as the golden rat tail. Many members of the Cactaceae family are the focus of chemical and biological studies as they contain bioactive compounds, well known for their health-related properties. We aimed to investigate Cleistocactus winteri stems both phytochemically and biologicallyfor the firs...
متن کاملSystem suitability in bioanalytical LC/MS/MS.
System suitability is widely recognized as a critical component of bioanalysis. This paper discusses a generic system suitability test that monitors instrument performance throughout a run when used for liquid chromatography tandem mass spectrometry (LC/MS/MS) in bioanalysis. This system suitability process is designed to ensure that the LC/MS/MS system is performing in a manner that leads to t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Bioanalysis
سال: 2016
ISSN: 2405-710X
DOI: 10.17145/jab.16.015