Calibration techniques of active BiCMOS mixers
نویسندگان
چکیده
منابع مشابه
Calibration Techniques of Active BiCMOS Mixers
This paper describes calibration techniques for downconversion mixers used in integrated direct-conversion receivers. A method of achieving a high even-order intermodulation rejection is presented. Using the method presented, the receiver second-order input intercept point (IIP2) can always be improved by more than 20 dB. The minimum achieved receiver IIP2 after calibration is +38 dBm. A techni...
متن کاملACTIVE MIXERS FOR DIRECT CONVERSION RECEIVERS WITH 0.35-μm BiCMOS
In this paper, the design requirements of different mixers for direct conversion receivers are discussed. Special attention has been paid into the detection of amplitude-modulated RF signal envelope. Three active mixers have been implemented to investigate the discussed requirements by using a 0.35-μm, 25-GHz BiCMOS technology. The same process allows an objective comparison between the differe...
متن کاملLinearization Techniques for Mixers
In the modern high-performance transceivers, mixers (both upand down-converters) are required to have large dynamic range in order to meet the system specifications. The lower end of the dynamic range is indicated by the noise floor which tells how small a signal may be processed while the high end is determined by the non-linearity which causes distortion, compression and saturation of the sig...
متن کاملGHZ Si BiCMOS ACTIVE INDUCTORS
The limitations on the implementation of BiCMOS active inductors at 2GHz are described. The circuit is based on a two BJT feedback configuration. Two types of biasing circuits were used: active bias and resistive bias. With 0.8μm BiCMOS standard technology is possible to obtain up to a few nanohenry inductance with a Q close to 3 at 2GHz. Two MMIC were studied.
متن کاملEstimation and Calibration of Robot Link Parameters with Intelligent Techniques
Abstract: Using robot manipulators for high accuracy applications require precise value of the kinematics parameters. Since measurement of kinematics parameters are usually associated with errors and accurate measurement of them is an expensive task, automatic calibration of robot link parameters makes the task of kinematics parameters determination much easier. In this paper a simple and easy ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Journal of Solid-State Circuits
سال: 2002
ISSN: 0018-9200
DOI: 10.1109/jssc.2002.1004581