Calibration of thermometer at low temperatures
نویسندگان
چکیده
منابع مشابه
Automated System for Thermometer Calibration
Calibration of thermometers is timeconsuming process that requires short-term temperature stability during multiple measurements at given temperature points. In most laboratories, thermometer calibration process is not automated, requiring the presence of the laboratory assistant during the calibration and for the subsequent calculation of the measurement uncertainty. In this paper, an automate...
متن کاملTwo-port microwave calibration at millikelvin temperatures.
In this work we introduce a system for 2-port microwave calibration at millikelvin temperatures operating at the coldest stage of a dilution refrigerator by use of an adapted thru-reflect-line algorithm. We show that this can be an effective tool for characterizing common 50 Ω microwave components with better than 0.1 dB accuracy at temperatures that are relevant to many current experiments in ...
متن کاملThe Nist Industrial Thermometer Calibration Laboratory
The NIST Industrial Thermometer Calibration (ITC) Laboratory provides calibrations of industrial thermometers over the range from –196 °C to 550 °C. The different types of thermometers include liquid-in-glass (LiG), thermistors, thermocouples (<200 °C), and industrial platinum resistance thermometers (IPRTs). Calibrations are performed by both comparison with a standard platinum resistance ther...
متن کاملSample environment at low temperatures
2014 A review of low temperature techniques as applied to neutron scattering studies is presented. Methods of temperature measurements especially carbon thermometry are discussed. Problems of heat transfer are treated in detail for different kind of samples and some solutions are proposed. Revue Phys. Appl. 19 (1984) 677-683 SEPTEMBRE 1984, The number of neutron scattering studies at temperatur...
متن کاملReset Noise at Low Temperatures
This paper presents results of the measurement and modelling of reset noise in charge-detection circuits of detector array multiplexers at low temperatures. To explain the temperature dependence of reset noise, it is proposed to take into account the source of noise associated with emission of electrons from interface states under the gate of reset transistor. It was found that at very low temp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)
سال: 1975
ISSN: 0389-2441,1880-0408
DOI: 10.2221/jcsj.10.84