Calibration-free wavelength modulation spectroscopy based on even-order harmonics
نویسندگان
چکیده
This paper proposes a novel and rapid calibration-free wavelength modulation spectroscopy algorithm based on even-order harmonics. The proposed algorithm, analytically deduced from Voigt line-shape function, only involves simple algebraic operations to describe the actual gas absorption spectra, thus eliminating time-consuming simulations fitting procedures adopted in traditional algorithms. Instead of acquiring entirely scanned line-shape, technique requires extraction peak values characteristic significantly benefits diagnosis at elevated pressure and/or temperature, which is very difficult be obtained due broadened line-shapes. validated by both numerical simulation condition-controlled experiment, indicating millisecond-level calculation parameters with relative error less than 4% experiments.
منابع مشابه
Odd harmonics with wavelength modulation spectroscopy for recovering gas absorbance shape.
In this paper, a new method for recovering gas absorbance shape using wavelength modulation spectroscopy is proposed. We have mathematically proven that the gas absorbance shape can be directly recovered using the data of X and Y components of odd harmonics, regardless of the value of the modulation depth. The transitions of NH(3) near 1531 nm are selected to recover the absorbance shape using ...
متن کاملRamsey-type spectroscopy with high-order harmonics.
We present an experiment where Ramsey-type spectroscopy is applied to autoionizing states of krypton by using the ninth harmonic (88 nm) of a femtosecond Ti:sapphire laser. The ionization process, detected by an electron-energy spectrometer, shows the characteristic quantum interference pattern. The behavior of the fringe contrast compares favorably with a simple essential-state model, whose pa...
متن کاملIn Situ H2o and Temperature Detection Close to Burning Biomass Pellets Using Calibration-free Wavelength Modulation Spectroscopy
The design and application of an H2O/temperature sensor based on scanned calibration-free wavelength modulation spectroscopy (CF-WMS) and a single tunable diode laser at 1.4 μm is presented. The sensor probes two H2O absorption peaks in a single scan and simultaneously retrieves H2O concentration and temperature by least-squares fitting simulated 1f-normalized 2f-WMS spectra to measured 2f/1f-W...
متن کاملQuasi-phase-matching of only even-order high harmonics.
High harmonic spectrum of a quasi-monochromatic pump that interacts with isotropic media consists of only odd-order harmonics. Addition of a secondary pump, e.g. a static field or the second harmonic of the primary pump, can results with generation of both odd and even harmonics of the primary pump. We propose a method for quasi-phase matching of only the even-order harmonics of the primary pum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2021
ISSN: ['1094-4087']
DOI: https://doi.org/10.1364/oe.432361