To develop a calibration curve for induction of dicentric chromosomes by radiation, we have used a 60Co gamma-ray source with dose rate of 12.5 mGy/s. Whole blood from 15 healthy donors was collected. Whole blood from each donor was divided equally into 8 parts for exposing to supposedly physical doses 0, 0.30, 0.50, 1.00, 1.50, 2.00, 3.00 and 4.00 Gy for a independent calibration curve. Whole ...

متن کامل

Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams

Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine th...

متن کامل

dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50mev proton beams

background: the purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. materials and methods: human peripheral blood lymphocytes were irradiated using proton beams (let: 34.6 kev μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (cb) micronucleus (mn) assay. to determine the efficie...

متن کامل

Determination of dose-response relationship in cultured human lymphocytes for biological dosimetry

Background: Lymphocyte-dicentric assay is the most generally accepted method for biological dosimetry of overexposed individuals. In this study, the frequency of unstable chromosome aberration in blood lymphocytes was used to estimate radiation dose received by individuals. Evaluation of dose using a calibration curve produced elsewhere may have a significant uncertainty therefore, experiments ...

متن کامل

In vitro radioprotective effects of histamine H2 receptor antagonist against gamma-rays induced chromosomal aberrations in human lymphocytes.

Background: Radioprotective capability of histamine H2 receptor antagonists have been shown in several in vivo studies mainly using animal models. However, to verify the effectiveness of these agents in clinical applications, studies should be performed on human cells. In the present study radioprotective properties of these agents was examined in vitro on human lymphocytes using metaphase anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Genome Integrity

سال: 2016

ISSN: 2041-9414

DOI: 10.4103/2041-9414.197171