CALIBRATING AND TESTING NEW ULTRACAM SENSORS
نویسندگان
چکیده
منابع مشابه
Calibrating and Testing New Ultracam Sensors
This contribution reports on the latest design of new UltraCam sensors. We present results from calibration and verification flights of the UltraCam Condor, which is based on a specific design and offers highest productivity from its 38000 pixel cross track image format. UltraCam Condor is based on the successful project experience with its predecessor, the UltraCam G.
متن کاملSynthesis and evaluation of self-calibrating ratiometric viscosity sensors.
We describe the design, synthesis and fluorescent profile of a family of self-calibrating dyes that provide ratiometric measurements of fluid viscosity. The design is based on covalently linking a primary fluorophore (reference) that displays a viscosity-independent fluorescence emission with a secondary fluorophore (sensor) that exhibits a viscosity-sensitive fluorescence emission. Characteriz...
متن کاملHls New Bpm Calibrating and Error Analysis*
A precise calibrating system for newly adopted beam position monitors (BPM) of upgraded injection system in NSRL phase II project is described. The fitting error of the electric field is presented. Using the calibrating system and the method which has a system error about ±15μm and the precision of 1μm, we have completed the calibration and checking of the quality to the developed equipment. Du...
متن کاملCalibrating Bulk Built-in Current Sensors for Detecting Transient Faults
This work presents a novel circuit for detecting transient faults in combinational and sequential logic. The detection mechanism features a built-in current sensor connected to the bulks of the monitored logic. The proposed circuit was optimized in terms of power consumption and enhanced with low-power sleep-mode. In addition, a calibration method for bulk built-in current sensors is presented....
متن کاملCalibrating Inverted Echo Sounders Equipped with Pressure Sensors
The addition of an accurate pressure sensor to the inverted echo sounder (IES) has allowed for the development of a new method for calibrating the IES’s acoustic travel-time record without the need for coincident conductivity– temperature–depth (CTD) or expendable bathythermograph profiles. Using this method, the round-trip traveltime measurement of the IES can be calibrated into various dynami...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences
سال: 2017
ISSN: 2194-9034