Calibrated Single-Contact Voltage Sensor for High-Voltage Monitoring Applications
نویسندگان
چکیده
منابع مشابه
A High Efficiency Low-Voltage Soft Switching DC–DC Converter for Portable Applications
This paper presents a novel control method to improve the efficiency of low-voltage DC-DC converters at light loads. Pulse Width Modulation (PWM) converters have poor efficiencies at light loads, while pulse frequency modulation (PFM) control is more efficient for the same cases. Switching losses constitute a major portion of the total power loss at light loads. To decrease the switching losses...
متن کاملHybrid Voltage Regulator for Low Voltage Applications
of the Thesis Fully Integrated Hybrid Voltage Regulator for Low Voltage Applications by Yongwan Park Master of Science in Electrical Engineering Stony Brook University 2016 A novel hybrid regulator topology is proposed to alleviate the weaknesses of existing hybrid topologies. Contrary to the dominant existing practice, a switchedcapacitor converter and a resistorless LDO operate in a parallel ...
متن کاملVoltage Sensor
The Tokamak Physics Experiment (TPX) was a steady-state, tokamak to be built at the Princeton Plasma Physics Laboratory. It would have been the first tokamak in the world with an entirely superconducting magnet system. The project was terminated by the United States Congress in 1995. However, most of the TPX mission has been adopted recently by the South Korean project KSTAR (Korean Superconduc...
متن کاملA high resolution and high linearity 45nm CMOS fully digital voltage sensor for low power applications
This paper proposes a design of voltage sensor with new controllable delay element (CDE) having high linearity and high resolution. The proposed CDE uses power supply node to measure the voltage value. However, the delay increases exponentially at low voltage level. In this paper we add a PMOS header in parallel with the conventional CDE to compensate the delay degradation at lower voltage. We ...
متن کاملConstant Voltage Contact Surface
LIDAR (laser radar) is used to measure three-dimensional(3-D) object positions. It produces a range and an intensity image ofthe measured object and relieson the range image to determine the 3-Dpositions of the object. But, the range image is frequently corrupted withnoise. A dynamic calibration method has been established to improvethe LIDAR accuracy basedon a polyn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Instrumentation and Measurement
سال: 2015
ISSN: 0018-9456,1557-9662
DOI: 10.1109/tim.2014.2360804