Calibrated Procedure for Setting Pulse-Height Parameters in Wavelength-Dispersive Spectrometry
نویسندگان
چکیده
منابع مشابه
Optimization of Wavelength Dispersive X-Ray Spectrometry Analysis Conditions
In setting up the conditions for quantitative wavelength-dispersive electron microprobe analysis a number of parameters have to be defined for each element, namely accelerating voltage, beam current, and (for each element) x-ray line, spectrometer crystal, pulse-height analyser settings, background offsets, and counting times for peak and background. The choices made affect both the reliability...
متن کاملA Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
متن کاملathree-wavelength pulse oximeter for carboxyhemoglobin determination
pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. this paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (hbco), by unfiltered leds at 660 nm, 810 nm, and 940 nm. background information is given on the theory of pulse oximetry. theoretical approximations and calculations w...
متن کاملA systematic procedure for setting parameters in simulated annealing algorithms
Values of parameters used in simulated annealing (SA) algorithms must be carefully selected since parameter values may have a significant influence on the performance of the algorithm. However, it is not easy to find good parameter values because values of a wide range have to be considered for each parameter and some parameters may be correlated with each other. In this paper, we suggest a pro...
متن کاملDetermination of Elemental Impurities in U308 by Wavelength-dispersive X-ray Fluorescence Spectrometry
Ten UsOs reference materials certified for impurities were used to develop the analytical procedure. A sequential wavelength dispersive X-ray spectrometer was used to perform the measurements. The measurement conditions were optimized to assure the best signal to background ratios and the minimum spectral interferences. Nineteen elements (Al, Bi, Ca, Co, Cr, Cu, Fe, Mg, Mn, MO, Na, Ni, Pb, Si, ...