Calculations of HREM Image Intensity Using Monte Carlo Integration
نویسندگان
چکیده
منابع مشابه
Neutron Transport Calculations Using Monte-Carlo Methods
Fusion reactions from direct-drive inertial confinement fusion experiments at the Laboratory for Laser Energetics (LLE) release large amounts of stored nuclear energy. Most of it is given off as energetic neutrons. Plastic scintillators are used as detectors for these neutrons. The neutrons that interact with the scintillator produce photons that are recorded using a photomultiplier tube on a f...
متن کاملMonte Carlo calculations
A Monte Carlo simulation using the PRESTA version of the EGS4 code has been employed as an investigative tool to calculate the absorbed dose in water close to 192Ir wire implants. It has been shown that a treatment planning system, such as GE Target II, using the Sievert integral and the Meisberger polynomial is only able to reproduce the Monte Carlo results at radial distances of 1 mm and fart...
متن کاملComparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کاملBenchmark quantum Monte Carlo calculations
Fixed node diffusion Monte Carlo !FN-DMC" atomization energies are calculated for a benchmark set of 55 molecules. Using single determinant trial wave functions, comparison with experiment yields an average absolute deviation of 2.9 kcal/mol, placing this simplest form of FN-DMC roughly at the same level of accuracy as the CCSD!T"/aug-cc-pVQZ method. However, unlike perturbative wave function e...
متن کاملDigital mammography image simulation using Monte Carlo.
Monte Carlo simulations of digital images of the contrast detail phantom and the ACR phantom are presented for two different x-ray digital mammography modalities: a synchrotron mammography system and a next-generation scanning slot clinical system. A combination of variance reduction methods made it possible to simulate accurate images using real pixel dimensions within reasonable computation t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2005
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927605503751