Calculation on Finned Tube Cooler Condensers
نویسندگان
چکیده
منابع مشابه
An improved tangency condition for fog formation in cooler-condensers
In 1950 Johnstone et al. (Ind. Engnq Chem. 42, 2298-2302 (1950)) introduced the tangency condition to determine fog (or mist) formation in binary mixtures in cooled channels. In the present analysis it is demonstrated that their condition is erroneous and an improved equation is derived. The condition is based on the heat and diffusional mass transfer rates to a condenser wall, and the slope of...
متن کامل10K Pulse Tube Cooler
A 3-stage pulse tube cooler has been designed to operate at 10¶K. The staged cooler uses the same compressor and parallel staging configuration for the 1 st and 2 nd stages as previously employed for our delivered High Capacity Cryocooler (HCC). The 2 nd and 3 rd stages are in a serial configuration. The addition of the third stage extends the performance of this cooler to lower operating tempe...
متن کاملNumerical Studies on the Performance of Finned-Tube Heat Exchanger
Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer such as tube pitch, tube diameter, tube thickness, etc... Finned-tube heat exchangers are common devices; however, their perfo...
متن کاملFull Analysis of Low Finned Tube Heat Exchangers
In this paper, first the governing parameters characterizing low-finned tubes are reviewed. Second, the more important of the available performance correlations are compared with the available experimental data. The most reliable one can be employed to develop a pressure drop relationship, which has already been used in an algorithm for exchanger sizing. Also a means for the identification of a...
متن کاملPerformance Evaluation Of Peripheral-Finned Tube Evaporators Under Frosting Conditions
The peripheral finned-tube (PFT) is a novel air-side geometry for compact heat exchangers. Previous studies (Pussoli et al., 2012) evaluated the thermal-hydraulic performance of the PFT geometry under dry conditions (i.e., no frost or condensate formation on the air side). The present study focuses on quantifying the thermal-hydraulic performance of the PFT geometry under frosting conditions. A...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemical engineering
سال: 1970
ISSN: 0375-9253
DOI: 10.1252/kakoronbunshu1953.34.292