Calculation of the electric field in GaAs particle detectors
نویسندگان
چکیده
منابع مشابه
The Electric Field in Irradiated Silicon Detectors
The electric eld distribution inside heavily irradiated silicon particle detectors is deduced using observations of particle and MIP signals. In these detectors particle signals are observed for both p and n side illumination even when the detector is only partially depleted . The observations indicate that the electric eld distribution within the detector has the contribution expected from a u...
متن کاملCryogenic ASICs in GaAs for Applications with Particle Detectors
We present two cryogenic Application Specific Integrated circuits (ASIC's) realized with a GaAs MESFET process. A single-channel differential or double-channel singleended voltage sensitive preamplifier for 4.2 K operation, to be used with bolometric detectors, was realized and tested. A very simple structure working as a unity gain buffer or as a transconductance amplifier, or even as a shapin...
متن کاملinvestigation of performance of semi-insulating gaas detectors for alpha particle detector
in this research work, alpha particle detector is made using semi-insulating gaas. a surface barrier detector with a semi-insulating gaas substrate at room temperature with pressure of 10-4 torr under -particle radiation with 5.48 mev of am241 source, have been under investigation. energy resolution of 2 and 3 mm schottky diameter have been matured and compared with the effect of voltage varia...
متن کاملDynamics of electric field screening in a bulk GaAs modulator.
The transient development of electric-field distributions in a biased GaAs film after low density optical excitation is determined by measurements of Franz-Keldysh modulations with a time resolution of 100 fs. The experimental results are compared with theoretical calculations. The transient field is calculated with a drift-diffusion model. Our calculation of the dielectric function of GaAs inc...
متن کاملMeasurement and Calculation of Electric Field Gradients in Hg-Mercaptides *
Electric field gradients (EFG) at Hg were determined in mercury mercaptides H g ( S ( C H 2 ) i C H 3 ) 2 experimentally for i e {0, 1, 2} using time differential perturbed angular correlation and theoretically for i e {0, 1} with the full potential linearized augmented plane wave code WIEN95. Due to the large unit cells and small hydrogen atoms not full convergence of the plane wave basis set ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1994
ISSN: 0168-9002
DOI: 10.1016/0168-9002(94)90501-0