CAD-based x-ray CT calibration and error compensation
نویسندگان
چکیده
Abstract Artifacts due to imperfect determination of the scanner geometry, beam hardening (BH), and diffuse Compton scattering, limit quantitative exploitation radiographs or tomographies for non-destructive evaluation. Exploiting computer-aided design (CAD) model an industrial part, a methodology is proposed refine estimation computed tomography (CT)-scanner geometry up scale factor, correct account artifacts, assess metrology part. A projective describing formation x-ray images in CT-scanners first introduced. The optimal parameters are identified using novel CAD-based calibration method that relies on registration simulated projections onto experimental ones. metrological analysis based comparison between acquired proposed. turbine blade, which automatic inspection procedure from few views under development, used as example illustrate methodology. parametrization accounts refinement projection BH, scattering. It shown that, procedure, differences radiographic significantly reduced, indicating properly identified. These then exploited detect flaws
منابع مشابه
Robust Frame Based X-ray Ct Reconstruction
As X-ray computed tomography (CT) is widely used in diagnosis and radiotherapy, it is important to reduce the radiation dose as low as reasonably achievable. For this purpose, one may use the TV based methods or wavelet frame based methods to reconstruct high quality images from reduced number of projections. Furthermore, by using the interior tomography scheme which only illuminates a region-o...
متن کاملGamma Calibration and Phase Error Compensation for Phase Shifting Profilometry
Phase Shifting Profilometry is a method of structured light whose three-dimensional reconstructions are susceptible to error from Gamma distortion. In practice, the luminance nonlinearity caused by the Gamma distortion effect of a digital video projector and a digital camera yields undesired fringe intensity changes, which substantially reduce the measurement accuracy, and while the effects of ...
متن کاملPhase contrast in laboratory-based X-ray CT
When scanning weakly attenuating samples using an X-ray tube with a very small focal spot size, the acquired projections not only contain absorption contrast, but also phase contrast due to refraction of the X-rays. Although the resulting edge enhancement can be beneficial in radiography, the tomographic reconstruction of such mixed projections using a conventional algorithm yields cross-sectio...
متن کاملFast Splitting-Based Ordered-Subsets X-Ray CT Image Reconstruction
Using non-smooth regularization in X-ray computed tomography (CT) image reconstruction has become more popular these days due to the recent resurgence of the classic augmented Lagrangian (AL) methods in fields such as totalvariation (TV) denoising and compressed sensing (CS). For example, undersampling projection views is one way to reduce radiation dose in CT scans; however, this causes strong...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Measurement Science and Technology
سال: 2022
ISSN: ['0957-0233', '1361-6501']
DOI: https://doi.org/10.1088/1361-6501/ac5133