BURIED SOIL PROFILE UNDER APRON OF AN EARTH FLOW
نویسندگان
چکیده
منابع مشابه
Soil-Structure Interaction of Buried Pipes Under Cyclic Loading Conditions
The safety of lifelines, as the most important urban facilities, under different conditions highly depends on the safe design and performance of these buried structures. This cannot be achieved unless their actual behaviors are well understood and considered at the designing stage. A new physical model was developed in Amirkabir University of Technology to study the behavior of buried pipes und...
متن کاملAn Electrochemical Measurement for Evaluating the Cathodic Disbondment of Buried Pipeline Coatings under Cathodic Protection
Steel pipelines are susceptible to corrosion by the action of corrosive substance in the environment and one of the most common failure modes in buried pipeline coatingis cathodic disbondment. Consequently, Electrochemical Impedance Spectroscopy (EIS) was used to assess the effect of three important parameters, the thickness of coating, the artificial defect ...
متن کاملA Buried Earth Analogue to Martian
J.P. Henriet, R. Wagner . E. Hauber, A. Chicarro, S. Di Lorenzo, G. Neukum and the HRSC Co-Investigator Team. RSSD of ESA. ESTEC, NL 2200 AG, Noordwijk, The Netherlands, [email protected]. 2 Challenger Division for Seafloor Processes, National Oceanography Centre, Southampton, United Kingdom. Renard Centre of Marine Geology, Department of Geology and Soil Science, Ghent University, Belgium In...
متن کاملAcoustic Imaging of Objects Buried in Soil
In this study, we demonstrate an acoustic system for high-resolution imaging of objects buried in soil. Our goal is to image cultural artifacts in order to assess in a rapid manner the historical significance of a potential construction site. We describe the imaging system and present preliminary images produced from data collected from a soil phantom. A mathematical model and associated comput...
متن کاملA SURVEY ON THE EFFECT OF SOIL COMPOSITION IN CORROSION BEHAVIOR OF CATHODICALLY PROTECTED BURIED PIPELINES UNDER AC INDUCED CONDITION
Abstract: Due to the expansion of high voltage Alternating Current (AC) power transmission lines and cathodically protected buried pipelines, it is becoming more and more difficult to construct them with enough safe distances between them. Thus, the pipelines are frequently exposed to induced AC interferences, which result in perturbation of Cathodic Protection (CP) due to AC corrosion. To s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Geological Society of America Bulletin
سال: 1967
ISSN: 0016-7606
DOI: 10.1130/0016-7606(1967)78[1183:bspuao]2.0.co;2