Bulk Etch Rate of LR 115 Polymeric Radon Detector

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

E ects of stirring on the bulk etch rate of LR 115 detector

The e ects of stirring on the bulk etch rate of LR 115 detector has been investigated. The surface pro6le measurement method using an instrument called Form Talysurf has been used to measure the thickness of the active layer of the LR 115 detectors. The etchant was 10% aqueous solution of NaOH maintained at 60◦C. The bulk etch rate under magnetic stirring has been found to be 6:65 ± 0:34 m h−1 ...

متن کامل

Measurement of bulk etch rate of LR 115 detector with atomic force microscopy

Equations for calculating track parameters have been proposed, which invariably involve the track etch rate Vt and the bulk etch rate Vb. The present study measured Vb for the LR115 solid-state nuclear track detector using atomic force microscopy (AFM). The detectors were partially masked using rubber cement and then etched in 2:5 N NaOH solution at 60◦C for time periods ranging from 5 to 40 mi...

متن کامل

Bulk etch characteristics of colorless LR 115 SSNTD

The colorless LR 115 solid-state nuclear track detector (SSNTD) (from DOSIRAD) is based on cellulose nitrate and was first studied in view of its applicability in radiobiological experiments with alpha particles. In this paper, the bulk etch characteristics were studied. We first showed that the shape of the alpha-particle tracks are irregular with blurred contours under the optical microscope....

متن کامل

Effect of Gamma Rays on The Bulk Etching Rate of LR-115 Detector

It is important to measure the bulk-etching rate for any solid state nuclear track detectors, because they have an application in different fields of sciences. The effect of gamma rays emitted from 60 Co source with different doses on LR-115 detector was studied. The bulk etching rate of the detectors was measured before and after irradiation using gamma source. From the results the values of t...

متن کامل

Estimation of Radon Exhalation Rate and Radium Content in Soil Samples of Pathankot District, Punjab Using LR-115 Plastic Detector

In the present investigation, soil samples were collected from 10 villages belonging to Pathankot district, Punjab, India and assessed for radium content using LR-115 plastic detector. The ‘track etch’ technique has been employed for measuring the radium content. From the radium content, radon exhalation rates and mass exhalation rates were calculated for these samples. The mass exhalation rate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Detection

سال: 2021

ISSN: 2331-2076,2331-2084

DOI: 10.4236/detection.2021.81001