Building inside air temperature parametric study

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and Numerical Investigation of Air Temperature Distribution inside a Car under Solar Load Condition

In this work both experimental and numerical analysis are carried out to investigate the effect of solar radiation on the cabin air temperature of Maruti Suzuki Celerio car parked for 90 min under solar load condition. The experimental and numerical analysis encompasses on temperature increment of air at various locations ins...

متن کامل

Parametric Study of Qutrigger Braced and Belt System in Tall Building Structures

Current innovative lateral load carrying systems for tall buildings are those in which the lateral drift is limited to an allowable value without considerable influence on economy. This aim is achieved by using special systems capable of using maximum stiffness and strength capacity of individual structural elements. An effective structural solution in this respect is the use of outrigger brace...

متن کامل

Parametric Study of Qutrigger Braced and Belt System in Tall Building Structures

Current innovative lateral load carrying systems for tall buildings are those in which the lateral drift is limited to an allowable value without considerable influence on economy. This aim is achieved by using special systems capable of using maximum stiffness and strength capacity of individual structural elements. An effective structural solution in this respect is the use of outrigger brace...

متن کامل

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

This paper presents results of a parametric study performed on an automotive air-conditioning (AAC) system of a passenger car. The goals are to assess the effects of varying the volumetric flow rate of supply air, number of occupants, vehicle speed, and the fractional ventilation air intake (XOA), on the dry-bulb temperature and specific humidity of the air inside the passenger’s cabin, and on ...

متن کامل

Equilibration of air temperature inside the thimble of a Farmer-type ion chamber.

Ionization chambers are frequently moved from one environment to another, sometimes with significant differences in temperature between the chamber and measurement phantom. To obtain reliable ionization data, the temperature of the air in the chamber must be allowed to equilibrate with the measuring phantom. The air temperature inside a thimble of a Farmer-type ion chamber was measured as a fun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magazine of Civil Engineering

سال: 2017

ISSN: 2071-4726,2071-0305

DOI: 10.5862/mce.68.7