Buffering zone of implantable Collamer lens sizing in V4c
نویسندگان
چکیده
منابع مشابه
Buffering zone of implantable Collamer lens sizing in V4c
BACKGROUND The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. METHODS V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), a...
متن کاملAuthor’s response to reviews Title: Buffering Zone of Implantable Collamer Lens Sizing in V4c Authors:
Title: Buffering Zone of Implantable Collamer Lens Sizing in V4c Authors: Seung Wan Nam ([email protected]) Dong Hui Lim ([email protected]) Joo Hyun ([email protected]) Eui-Sang Chung ([email protected]) Tae-Young Chung ([email protected]) Version: 1 Date: 04 Sep 2017 Author’s response to reviews: Alja Crnej (Reviewer 1): 1. Page 8, line 130 how did you decide what was too large what w...
متن کاملComparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia
The aim of this study was to investigate the visual quality of the 2 kinds of intraocular lens: Visian implantable collamer lens (ICL) V4 and Visian ICL V4c implantations for high myopia.Twenty cases (20 eyes) with high myopia who received Visian ICL V4 implantation and 18 cases (18 eyes) with high myopia who received Visian ICL V4c implantation in our hospital from April 1, 2014 to November 31...
متن کاملImplantable collamer lens V4b and V4c for correction of high myopia
PURPOSE To evaluate the visual outcome and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with central hole) for correction of high myopia. METHODS A prospective, consecutive, interventional comparative case series of V4b and V4c ICL implantation was done in high myopic patients who were unsuitable for laser vision. The main outcome measure...
متن کاملMeasurement of the crystalline lens radius with artemis very high frequency ultrasound biomicroscopy for implantable collamer lens sizing.
To the Editor: In their recent article, Reinstein et al.1 described the use of the Artemis 2 very high frequency digital ultrasound (ArcScan, Inc., Morrison, CO) to calculate the fit of the Visian Implantable Collamer Lens (ICL). Another parameter previously proposed as influencing ICL vaulting is the crystalline lens anterior radius of curvature (ALR).2 The ALR has not yet been used in any pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMC Ophthalmology
سال: 2017
ISSN: 1471-2415
DOI: 10.1186/s12886-017-0663-4