Bubble CPAP versus CPAP with variable flow in newborns with respiratory distress: a randomized controlled trial
نویسندگان
چکیده
منابع مشابه
Bubble CPAP versus CPAP with variable flow in newborns with respiratory distress: a randomized controlled trial.
OBJECTIVE To evaluate the efficacy and safety of nasal continuous positive airway pressure (NCPAP) using devices with variable flow or bubble continuous positive airway pressure (CPAP) regarding CPAP failure, presence of air leaks, total CPAP and oxygen time, and length of intensive care unit and hospital stay in neonates with moderate respiratory distress (RD) and birth weight (BW) ≥ 1,500 g. ...
متن کاملBubble–CPAP vs. Ventilatory–CPAP in Preterm Infants with Respiratory Distress
OBJECTIVE Application of Continuous Positive Airway Pressure (CPAP) in neonate with respiratory distress is associated with reduction of respiratory failure, reduced complications and mortality. Bubble CPAP (B-CPAP) and ventilator-derived CPAP (V-CPAP) are two most popular CPAP modes. We aimed to determine whether B-CPAP and V-CPAP would have different survival rate and possible complications. ...
متن کاملBubble CPAP - a primary respiratory support for respiratory distress syndrome in newborns.
In preterm infants with respiratory distress syndrome (RDS), the application of continuous positive airway pressure (CPAP) is associated with benefits in terms of reduced respiratory failure and reduced mortality. We conducted this prospective study to evaluate the effectiveness of bubble-CPAP as primary mode of respiratory support. Bubble CPAP was found to be safe and effective means of treati...
متن کاملVolume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial
Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...
متن کاملComparison of the Therapeutic Effects of Bubble CPAP and Ventilator CPAP on Respiratory Distress Syndrome in Premature Neonates
Background: Respiratory distress syndrome is one of the main complications associated with low birth weight, and a main cause of mortality in premature neonates. The present study aimed to compare the efficacy of ventilator continuous positive airway pressure (CPAP) and bubble CPAP in the treatment of respiratory distress syndrome (RDS) in premature neonates. Methods: This randomized controlled...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Jornal de Pediatria
سال: 2011
ISSN: 0021-7557
DOI: 10.2223/jped.2145