Bronchial blocker for one-lung ventilation: An unanticipated complication

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporary solution for one lung ventilation with isolated bronchial blocker of Univent® tube

Corresponding author: Junyong In, M.D., Department of Anesthesiology and Pain Medicine, Dongguk University Ilsan Hospital, 814, Siksadong, Ilsandong-gu, Goyang 410-773, Korea. Tel: 82-31-961-7875, Fax: 82-31-961-7864, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/lice...

متن کامل

High Frequency Jet Ventilation of One Lung using a Bronchial Blocker of Univent during Carinal Resection

Airway management during carinal resection should provide adequate ventilation and oxygenation as well as a good surgical field, but without complications such as barotraumas or aspiration. One method of airway management is high frequency jet ventilation (HFJV) of one lung or both lungs. We describe a patient undergoing carinal resection, who was managed with HFJV of one lung, using a de-ballo...

متن کامل

Independent Lung Ventilation and One Lung Ventilation

The application of the independent lung ventilation (ILV) in adults has been described by Carlon and co-workers in 1978 and subsequently by other investigators. In 1983 Hedenstierna and coworkers using a bilumen tube suitable for prolonged intubation, and two Servo Ventilator 900 B (Siemens) adapted for synchronization, treated a wide range of clinical conditions. Following this experience, the...

متن کامل

Use of the univent bronchial-blocker tube for unanticipated difficult endotracheal intubation.

To the Editor:—In the face of difficult intubation, it is sometimes useful to insert a small-diameter introducer through the laryngeal aperture in the trachea and then pass the endotracheal tube over it. We report a modification of this technique using the Univent bronchial-blocker tube (Fuji System, Tokyo, Japan) in a patient with unanticipated difficult intubation. A 60-yr-old, 67-kg man with...

متن کامل

Protective strategies for one-lung ventilation

provided the original work is properly cited. CC Hypoxemia and acute lung injury (ALI) are major concerns with one-lung ventilation (OLV) during thoracic surgery. Hypoxemia is usually the result of alveolar hypoventilation and an increasing shunt fraction, whereas ALI is caused by ventilatory stress (volutrauma, atelectrauma, and barotrauma), reexpansion pulmonary injury, and the lung surgery i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Indian Journal of Anaesthesia

سال: 2011

ISSN: 0019-5049

DOI: 10.4103/0019-5049.90638