Broken pedicle screw thread extraction from within the pedicle

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pedicle screw placement in patients with variant atlas pedicle

OBJECTIVE To investigate how the anatomy of variant atlas vertebra impacts on the strategy used to place pedicle screws used to treat atlantoaxial instability. METHODS The study enrolled patients with cervical instability who had a posterior arch pedicle height <3.5 mm at the anchor point, a vertebral artery groove height <3.5 mm, or both. Pedicle screws were fitted according to the anatomy o...

متن کامل

Pedicle screw fixation in the spine.

In August 1993, in the USA, an FDA advisory committee of experts reviewed the scientific data on pedicle screws and decided that not enough was known about the shortterm problems or the long-term safety and effectiveness of these devices to allow their use to be approved. Manufacturers were therefore forbidden to promote the use of screws in the spine, and patients were warned that pedicle scre...

متن کامل

The biomechanics of pedicle screw-based instrumentation.

There are three basic concepts that are important to the biomechanics of pedicle screw-based instrumentation. First, the outer diameter of the screw determines pullout strength, while the inner diameter determines fatigue strength. Secondly, when inserting a pedicle screw, the dorsal cortex of the spine should not be violated and the screws on each side should converge and be of good length. Th...

متن کامل

Guided pedicle screw insertion: techniques and training.

BACKGROUND CONTEXT In spinal fusion surgery, the accuracy with which screws are inserted in the pedicle has a direct effect on the surgical outcome. Accurate placement generally involves considerable judgmental skills that have been developed through a lengthy training process. Because the impact of misaligning one or more pedicle screws can directly affect patient safety, a number of navigatio...

متن کامل

Pedicle screw malposition following spinal lumbar injury

Pedicle screws are the main type of instrumentation used in the lumbar spine via the posterior approach. The accuracy of their insertion is always a concern because the malposition of screws is associated with a potential risk of iatrogenic injury of any neurovascular structure they pass. Fortunately, spinal cord and cauda equina injuries are rare. This 18-year-old paraplegic woman presented mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Annals of The Royal College of Surgeons of England

سال: 2016

ISSN: 0035-8843,1478-7083

DOI: 10.1308/rcsann.2016.0080