Breath-by-breath quantification of progressive airflow limitation during exercise in COPD: A new method
نویسندگان
چکیده
منابع مشابه
solution of security constrained unit commitment problem by a new multi-objective optimization method
چکیده-پخش بار بهینه به عنوان یکی از ابزار زیر بنایی برای تحلیل سیستم های قدرت پیچیده ،برای مدت طولانی مورد بررسی قرار گرفته است.پخش بار بهینه توابع هدف یک سیستم قدرت از جمله تابع هزینه سوخت ،آلودگی ،تلفات را بهینه می کند،و هم زمان قیود سیستم قدرت را نیز برآورده می کند.در کلی ترین حالتopf یک مساله بهینه سازی غیر خطی ،غیر محدب،مقیاس بزرگ،و ایستا می باشد که می تواند شامل متغیرهای کنترلی پیوسته و گ...
Measurement of breath-by-breath gas exchange during general anaesthesia.
We describe a single flow transducer breath-by-breath gas exchange measurement system suitable for use during general anaesthesia. The system uses a Fleisch No. 2 pneumotachograph, a mass spectrometer and a microcomputer to give real-time continuous measurements. Correction for apparent gas exchange attributable to changes in gas stored in the lung (functional residual capacity) is available. T...
متن کاملAirflow obstruction and roadside breath alcohol testing.
FIGURE 1. Bar graph shoiwing distribution oil FVC in study population. Heavily shaded sections represent the three subjects who could not dot the test. Lightly shaded sections represent asthmatic patients. Clear sections represent COPD patients. communications to the editor Communications for this section will be published as space and priorities permit. The comments should not exceed 350 words...
متن کاملExhaled breath condensates and COPD.
BORRILL et al. [1] have recently provided a timely review of exhaled breath condensates (EBC) in chronic obstructive pulmonary disease. However, there are several issues that deserve comment. BORRILL et al. [1] argue that although it would be useful to use dilutional indicators for estimating the dilution of respiratory droplets from the airway lining fluid (ALF) by water vapour, none of these ...
متن کاملThe use of a new breath-actuated inhaler by patients with severe airflow obstruction.
The ability of patients with severe airflow limitation (forced expiratory volume in one second less than 1.0 l or peak expiratory flow rate less than 200 l.min.1) to use a new breath-actuated inhaler (BAI) was assessed. One hundred and fifty six patients attending two respiratory units entered and completed the study. Subjects were instructed how to use the device and after attempting to trigge...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Respiratory Medicine
سال: 2010
ISSN: 0954-6111
DOI: 10.1016/j.rmed.2009.10.014