Breakdown characteristics of combined air gaps under lightning impulse

نویسندگان

چکیده

With the increase of both voltage level and transmission capacity, more attention has been paid to external insulation lines. As main medium line, air gap’s dielectric strength will change when there are floating conductors. In this paper, we established an experiment platform study effects conductors, simulated by rod electrode, on breakdown voltage, time, electric field distribution discharge physical process long gaps under lightning impulse. The results showed that intervention electrode reduced time gaps, position with longest was same as lowest voltage. addition, improved spatial complexity process.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Humidity on the Breakdown of Air Gaps under Oscillatory Switching Impulse Voltages - Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on

Experimental investigations were carried out to study the effect of humidity on the breakdown of rod-plane gaps subjected to both uni-directional and bi-directional oscillatory switching impulse voltages. The humidity ranged from 14.1 36 gm/m3 at a constant temperature of 40' C. The gap subjected to uni-directional 6.3, 10, lQ kHz and bi-directional 4.2, 10,20 kHz oscillatory switching impulse ...

متن کامل

Lightning Impulse Ageing of Hdpe

This work is concerned with the hypothesis that lightning impulses can lead to accelerated ageing of extruded polymeric cables. The behaviour of an insulation material when suffering lightning impulses is different from that for DC or power frequency over-voltages. Shaped HDPE material samples have been manufactured using a mould tool. The samples then may be electrically aged using one of the ...

متن کامل

Lightning Impulse Ageing of Hv Cable Insulation

Lightning impulses can lead to accelerated ageing of extruded cables. Electrical behaviour of a dielectric material when experiencing a lightning impulse is different to that for DC or power frequency applied voltages. Pre-designed shaped HDPE material samples have been manufactured using a mould tool. The samples then have been electrically aged using an impulse generator. A real-time software...

متن کامل

Using Subgridding FDTD Method to Incorporate Air Gap Breakdown in the Analysis of Lightning Induced Voltage

A subgridding formulation of Agrawal coupling equations of transmission line with branch and distributed electromagnetic excitation is proposed. This algorithm enables us to solve the transmission line system using different temporal and spatial step on different branches. The method is used to calculate the lightning induced over-voltage on the transmission line installed with air gap componen...

متن کامل

Effect of Cross-linking on the Electrical Properties of Ldpe and Its Lightning Impulse Ageing Characteristics

Cross-linked polyethylene (XLPE) is commonly used within high voltage cable insulation. It has improved thermal and mechanical resistance compared to normal low density polyethylene (LDPE). However, the cross-linking process may also vary the electrical characteristics of the material. This paper investigates changes in electrical properties of one type of LDPE before and after cross-linking. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: AIP Advances

سال: 2022

ISSN: ['2158-3226']

DOI: https://doi.org/10.1063/5.0084951