Brachytherapy dose‐volume histogram commissioning with multiple planning systems

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brachytherapy dose‐volume histogram commissioning with multiple planning systems

The first quality assurance process for validating dose-volume histogram data involving brachytherapy procedures in radiation therapy is presented. The process is demonstrated using both low dose-rate and high dose-rate radionuclide sources. A rectangular cuboid was contoured in five commercially available brachytherapy treatment planning systems. A single radioactive source commissioned for QA...

متن کامل

Addendum to brachytherapy dose‐volume histogram commissioning with multiple planning systems

The process for validating dose-volume histogram data in brachytherapy software is presented as a supplement to a previously published article. Included is the DVH accuracy evaluation of the Best NOMOS treatment planning system called "Best TPS VolumePlan." As done previously in other software, a rectangular cuboid was contoured in the treatment planning system. A single radioactive 125I source...

متن کامل

Commissioning of brachytherapy module of Oncentra MasterPlan treatment planning system

PURPOSE To describe the tests that have been performed in order to commission the Brachytherapy module, version 3.2, service pack 3.0, of the Oncentra MasterPlan treatment plan system (OB), from Nucletron. The results were benchmarked against those obtained with the Plato system, v 14.3.7, also from Nucletron, used in the clinical routine. MATERIAL AND METHODS Commissioning was performed taki...

متن کامل

A commissioning procedure for breast intracavitary electronic brachytherapy systems

In this work, we report a comprehensive quality assurance (QA) process for the commissioning of an Electronic Brachytherapy (EB) system at one of the first U.S. sites to apply the device clinically. Thus far, EB systems have been released only for intracavitary breast treatments. As such, EB as an Accelerated Partial Breast Irradiation (APBI) treatment modality is relatively unstudied and is un...

متن کامل

Quality Assurance Procedures based on Dosimetric, Gamma Analysis as a Fast Reliable Tool for Commissioning Brachytherapy Treatment Planning Systems

Background Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and planar film dosimetry is also increasingly used for verification of the dose distribution in BT applications. Using the gamma analysis m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2014

ISSN: 1526-9914,1526-9914

DOI: 10.1120/jacmp.v15i2.4620