Bowel obstruction due to retained intraperitoneal left ventricular assist device (LVAD) driveline
نویسندگان
چکیده
منابع مشابه
Stroke and Left Ventricular Assist Device (LVAD)
Treatment of ischemic stroke for a patient on left ventricular assist device (LVAD) by neurointerventional means is rare and many anesthesia providers are unfamiliar with both LVAD and neurointerventional protocols. Examples of this include: 1) filling for continuous-flow LVAD depend on preload and the flow is inversely related to afterload; as mean arterial pressure (MAP) increases above 80 to...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملA Rare Cause of Left Ventricular Assist Device (LVAD) Obstruction: Left Atrial Dissection
Left atrial dissection is a rare factor that may cause left ventricular assist device obstruction. Prompt diagnosis and surgical repair are essential. This case report describes our experience and a successful surgical management in a patient after HeartMate 3 implantation and mitral valve inflow obstruction due to a left atrial dissection.
متن کاملDynamic left ventricular assist device inflow obstruction.
A 72-year-old man with a history of rheumatic heart disease , prior bioprosthetic mitral and aortic valve replacement , severe nonischemic dilated cardiomyopathy (left ventricular [LV] ejection fraction 5%), and a history of ven-tricular tachycardia (VT) underwent implantation of a continuous flow LV assist device (LVAD; HeartMate II; Thoratec Corporation) as destination therapy for severe hear...
متن کاملimprovement of left ventricular assist device (lvad) in artificial heart using particle swarm optimization
in this approach, the left ventricular assist pump for patients with left ventricular failure isused. the failure of the left ventricle is the most common heart disease during these days. inthis article, a state feedback controller method is used to optimize the efficiency of a samplingpump current. particle swarm algorithm, which is a set of rules to update the position andvelocity, is applied...