Boundary condition effect on response modification factor of X-braced steel frames
نویسندگان
چکیده
منابع مشابه
Evaluating Response Modification Factors of Concentrically Braced and Special Moment Steel Frames in Duplex Buildings
Response modification factor (R-factor) is one of the seismic design parameters to consider nonlinear performance of building structures during strong earthquake. Relying on this, many seismic design codes led to reduce earthquake loads imposed to the structure. The present paper tries to evaluate the R-factors of conventional concentric braced frames (CBFs) and special moment frames (MRFs) in ...
متن کاملevaluating response modification factors of concentrically braced and special moment steel frames in duplex buildings
response modification factor (r-factor) is one of the seismic design parameters to consider nonlinear performance of building structures during strong earthquake. relying on this, many seismic design codes led to reduce earthquake loads imposed to the structure. the present paper tries to evaluate the r-factors of conventional concentric braced frames (cbfs) and special moment frames (mrfs) in ...
متن کاملResponse Modification Factor of Coupled Steel Shear Walls
The present research is concerned with the determination of ductility, over-strength and response modification factors of coupled steel shear wall frames. Three structural models with various numbers of stories, bay width and coupling beam height were analyzed using static pushover and incremental nonlinear dynamic analyses. The ductility, over-strength and response modification factors for the...
متن کاملPERFORMANCE-BASED CONNECTION TOPOLOGY OPTIMIZATION OF UNBRACED AND X-BRACED STEEL FRAMES
The present study sets out to integrate the performance-based seismic design approach with the connection topology optimization method. Performance-based connection topology optimization concept aims to simultaneously optimize the size of members and the type of connections with respect to the framework of performance-based seismic design. This new optimization concept is carried out for unbrac...
متن کاملResponse Modification Factor of Chevron Braced Frame With Pall Friction Damper
Response modification factors (R-factor) are used in current seismic building codes to reduce earthquake forces associated with seismic design level to determine force levels. In recent years, many authors have shown great interest in the development of seismic structural systems and several theoretical and experimental studies have been conducted to investigate performance of dampers but littl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: HBRC Journal
سال: 2018
ISSN: 1687-4048,1687-4048