Boric Acid Corrosion of Concrete Rebar

Borated water leakage through spent fuel pools (SFPs) at pressurized water reactors is a concern because it could cause corrosion of reinforcement steel in the concrete structure and compromise the integrity of the structure. Because corrosion rate of carbon steel in concrete in the presence of boric acid is lacking in published literature and available data are equivocal on the effect of boric...

متن کامل

Final Report an Evaluation of New Inhibitors for Rebar Corrosion in Concrete

ii DISCLAIMER The contents of this report reflect the views of the authors, who are responsible for the facts and the accuracy of the data presented herein. The contents do not necessarily reflect the official views or policies of the Virginia Department of Transportation, the Commonwealth Transportation Board, or the Federal Highway Administration. This report does not constitute a standard, s...

متن کامل

08311 - Corrosion of Epoxy Coated Rebar in Cracked Marine Substructure Concrete

Epoxy coated reinforcement (ECR) has been used in Florida from the 1970s to 1990s but has been discontinued due to the observation of severe corrosion in some ECR bridges after short service times. Corrosion projections have been made in earlier investigations based on corrosion initiation and propagation concepts but did not consider the presence of structural cracks. The current research in p...

متن کامل

Corrosion Performance of Stainless Steel Clad Rebar in Simulated Pore Water and Concrete

The corrosion performance of stainless steel clad reinforcing bar (SCR) was investigated. Corrosion potential of SCR in various alkaline media as a function of time was measured periodically and corrosion rates were estimated using Electrochemical Impedance Spectroscopy (EIS). At room temperature, SCR without cladding breaks was free of corrosion for up to one year in all the testing conditions...

متن کامل

CORROSION BEHAVIOR OF ZINC COATED STEEL REBAR IN HIGH-STRENGTH REINFORCED CONCRETE

A large number of reinforced concrete structures subjected to chloride ions. Two basicapproaches for preventing corrosion of reinforcing steel embedded in concrete are: Increasing theconsolidation of concrete and using different coating on rebars. In present research steel rebarsare coated in different ways: a) 40 µm of zinc electroplated on steel rebar b) Zinc powder withepoxy paste (zinc rich...