Bone turnover markers are correlated with total skeletal uptake of 99mTc-methylene diphosphonate (99mTc-MDP)

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone turnover markers are correlated with total skeletal uptake of 99mTc-methylene diphosphonate (99mTc-MDP)

BACKGROUND Skeletal uptake of 99mTc labelled methylene diphosphonate (99mTc-MDP) is used for producing images of pathological bone uptake due to its incorporation to the sites of active bone turnover. This study was done to validate bone turnover markers using total skeletal uptake (TSU) of 99mTc-MDP. METHODS 22 postmenopausal women (52-80 years) volunteered to participate. Scintigraphy was p...

متن کامل

Bone turnover markers are correlated with total skeletal uptake of 99 mTc - methylene diphosphonate ( 99 mTc

Background: Skeletal uptake of 99mTc labelled methylene diphosphonate (99mTc-MDP) is used for producing images of pathological bone uptake due to its incorporation to the sites of active bone turnover. This study was done to validate bone turnover markers using total skeletal uptake (TSU) of 99mTc-MDP. Methods: 22 postmenopausal women (52–80 years) volunteered to participate. Scintigraphy was p...

متن کامل

Incidental thyroid uptake during 99mTc-methylene diphosphonate bone scintigraphy in oncologic patients

Introduction: Extraosseous accumulation of 99mTc – methylene diphosphonate (MDP) may be due to neoplastic, dystrophic, hormonal, inflammatory, ischemic, traumatic or excretory disorders. 99mTc-MDP incidental thyroid uptake is not frequent and is possibly caused by the presence of dystrophic or metastatic calcification, biopsy procedure and presence of beni...

متن کامل

SPECT-CT for characterization of extraosseous uptake of 99mTc-methylene diphosphonate on bone scintigraphy.

Bone scintigraphy is a sensitive and popular method for imaging a wide array of benign or malignant skeletal abnormalities. However, the uptake of tracers used for bone scintigraphy may be observed in various extraosseous sites, thereby limiting its specificity. It is difficult to correctly localize such sites of uptake on planar bone scintigraphy alone. The addition of hybrid single-photon emi...

متن کامل

Extra-osseous 99mTc methylene diphosphonate uptake detected enlargement of the knee joint in patient with polyarthritis

Bone scintigraphy is a nuclear scanning test used to find abnormalities in the skeleton. Certain abnormal processes involving soft tissues can also cause skeletal accumulation of radiotracer during bone scintigraphy. We present a case of periarticular knee soft tissue 99mTc methylene diphosphonate uptake in a patient with asymmetric polyarthritis. A 33-year-old patient with asymmetric polyarthr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BMC Medical Physics

سال: 2009

ISSN: 1756-6649

DOI: 10.1186/1756-6649-9-3