Bond strength characterization of concrete filled steel tube as structural member

نویسندگان

چکیده

Studies done by the previous researchers in Concrete Filled Steel Tubes (CFST) have a significant focus on bond performance of CFST. This paper includes studies evaluation critical parameters such as interface condition, length, infilled concrete strength, and end friction cross-section dimension these members. It is found that effect length had very little impact stress it shows promising value when range 200-800 mm after that, gets shifted reduced for larger length. But this decrease affiliated with other parameters, like macro-locking, compressive strength distinctly affects mean sample regular most part increases strength. spotted coefficient 0.15 used at both column ends to provide fixity becomes clear local buckling pattern stub independent friction. In categories columns, among steel tube extraordinarily increased cross-sectional dimension.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes

In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...

متن کامل

Flexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections

The sections composed of concrete and steel, which include concrete-encased concrete-filled tubes, generally have defects due to the low tensile strength of concrete. Therefore, an appropriate method was used for the combination of concrete-filled tubes (CFT) and prestressing strands which is encased in concrete. The conventional design guidelines are commonly developed for materials with norma...

متن کامل

Bond of High Strength Concrete with High Strength Reinforcing Steel

This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete ...

متن کامل

Cyclic Evolution of Damage and Beam-column Interaction Strength of Concrete-filled Steel Tube Beam-columns

The assessment of response of composite seismic force resisting systems requires accurate nonlinear formulations for the composite members. In this work, reporting the first phase of a NEES project, a three-dimensional distributed plasticity formulation is presented for both circular and rectangular composite concrete-filled steel tubes (CFTs) that includes new constitutive models for the concr...

متن کامل

Behavior of FRP-Confined Concrete-Filled Steel Tube Columns

This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP). Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Electronic Journal of Structural Engineering

سال: 2022

ISSN: ['1443-9255']

DOI: https://doi.org/10.56748/ejse.223002