Bond behaviour of high-strength steel rebars in normal (NSC) and ultra-high performance concrete (UHPC)
نویسندگان
چکیده
منابع مشابه
Bond of High Strength Concrete with High Strength Reinforcing Steel
This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete ...
متن کاملEffect of Reinforcement Type on the Tension Stiffening Model of Ultra-High Performance Concrete (UHPC)
Ultra-high performance concrete (UHPC) is a developing concrete and today is increasing to interest using it in structures due to its advantages such as high-compressive strength, modulus of elasticity, highly durability and low-permeability. Therefore, it is necessary to provide models for prediction of nonlinear behavior of this material. This study is aimed to investigate the tension-stiffen...
متن کاملSlippage of Steel in High and Normal Strength Concrete
Composite action of any reinforced concrete member is only possible if sufficient bond strength exists between steel reinforcing bars and concrete, which can adequately transfer shear stress between them. Bond strength is a function of compressive strength of concrete and hence high strength concrete has higher bond strength [1-2]. Therefore required development length can be reduced. In order ...
متن کاملFlexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections
The sections composed of concrete and steel, which include concrete-encased concrete-filled tubes, generally have defects due to the low tensile strength of concrete. Therefore, an appropriate method was used for the combination of concrete-filled tubes (CFT) and prestressing strands which is encased in concrete. The conventional design guidelines are commonly developed for materials with norma...
متن کاملBond of Reinforcement in High-Strength Concrete
This paper describes an examination of the development of tension lap splices in high-strength concrete and the applicability of the restriction in the ACI 318 code where the values of √fc′ used to calculate development length shall not exceed 100 psi. The focus is on the development of splices with Grade 60 epoxy-coated and uncoated bars in normalweight concrete. A summary of the behavior of b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Building Engineering
سال: 2021
ISSN: 2352-7102
DOI: 10.1016/j.jobe.2020.101592