Bolt stripping failure and ductility of end plate beam-column connections at ambient and elevated temperatures
نویسندگان
چکیده
Purpose The effect of bolt stripping failure on the ductility steel end plate beam-column connections has received relatively little investigation to date. objective with present work is establish a validated numerical model at elevated temperatures, which predicts mechanical behaviour and modes observed in experimental tests including failure. Furthermore, FE was used investigate both rotational load-bearing capacity connection. Design/methodology/approach analysis conducted material modelled considering ductile damage initiation evolution featured ABAQUS/Standard. Findings This study demonstrates that thick plates can prevent significantly improves mode develop readily thin plates; however often unrealistically mitigated through idealised tests. connection be 5.0 times higher if avoided, particularly temperatures. Eurocode 3 part 1.8 does not consider possibility when discussing requirements for plastic analysis. It concluded by allowing stripping, shift from this turn reduces capacity. Originality/value
منابع مشابه
A Study on the Ductility of Bolted Beam - Column Connections
The behaviour of beam-column joint plays an important role in the response of a steel moment resisting framed structure especially under seismic excitation. Semi rigid connections like bolted joints, allow better energy dissipation and provide good response under lateral loads. In this paper the ductility and energy dissipation characteristics of semi rigid bolted connections using double web a...
متن کاملمطالعه آزمایشگاهی رفتار اتصالات عرشه سکوهای نفتی در آتشسوزی
Beam-to-column connections have been found to be of great significance in influencing structural behavior at ambient and elevated temperatures. Observations from full-scale fire tests and damaged structures confirm that connections have a considerable effect on the stability time of structural components in fire. Due to the high cost of elevated temperature tests, adequate experimental data abo...
متن کاملDesign of Cold-Formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures
Abstract: Load-bearing cold-formed steel (CFS) walls sheathed with double layers of gypsum plasterboard on both sides have demonstrated good fire resistance and attracted increasing interest for use in mid-rise CFS structures. As the main connection method, screw connections between CFS and gypsum sheathing play an important role in both the structural design and fire resistance of this wall sy...
متن کاملThe Behavior of Type of RC Column-to-Steel Beam Connections and Scrutiny Of Behavior Coefficients
(RCS) frames which are systems that dwell of concrete columns and steel beams , by optimizing the act of compressive strength of concrete and bending strength of steel due to not only a decrease in building weight in comparison to concrete structures but also having a better action in long spans frames . In this paper for analysis RCS behavior, a category of nonlinear Push Over analyses were ...
متن کاملNumerical Analysis of Cyclic Behavior of Beam-To-Column Bolted Connections in Steel Frames
This article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. As the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. Four different specimens have been analyzed. These models had some differences such as bolt arrangement and the presence or a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural Fire Engineering
سال: 2022
ISSN: ['2040-2317', '2040-2325']
DOI: https://doi.org/10.1108/jsfe-02-2022-0009