Body surface distribution of electrical potential during atrial depolarization and repolarization.
نویسندگان
چکیده
منابع مشابه
Body surface distribution of electrical potential during atrial depolarization and repolarization.
Limited information is available documenting body surface isopotential distributions during atrial excitation and recovery. To expand the current data base, body surface isopotential maps from 40 normal subjects were examined. Data were acquired at a gain of 10,000 and isopotential distributions constructed at 2-msec intervals from the onset of the P wave to the onset of the QRS complex. During...
متن کاملBody surface distribution of equipotential lines during atrial depolarization and ventricular repolarization.
متن کامل
Electrical potential distribution surrounding the atria during depolarization and repolarization in the dog.
The potential distribution at the atrial surface during depolarization and repolarization was studied in intact dogs. A preparation was developed by implanting 30 to 40 miniature electrodes permanently on each atrium to record unipolar electrograms in the intact animal. Heart block was created to dissociate atrial and ventricular activity. The electrograms were recorded on magnetic tape and atr...
متن کاملImaging electrocardiographic dispersion of depolarization and repolarization during ischemia: simultaneous body surface and epicardial mapping.
BACKGROUND Myocardial ischemia creates abnormal electrophysiological substrates that result in life-threatening ventricular arrhythmias. Identifying patients at risk of such abnormalities by use of body surface electrical measures is controversial. We investigated the sensitivity of torso measures, recorded simultaneously with epicardial electrograms, to changes in dispersion of depolarization ...
متن کاملAssessment of Heart Repolarization Properties from Body Surface Potential Maps
Use of activation-recovery interval (ARI) in surface ECG leads as possible indicator of changed repolarization in the underlying myocardium was studied. Model ECG data representing normal and pathological myocardium repolarization were simulated on surface of realistic inhomogeneous torso. Results of simulations suggest that shortening and prolongation of action potentials in anterior myocardia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Circulation
سال: 1980
ISSN: 0009-7322,1524-4539
DOI: 10.1161/01.cir.62.1.167