Blood-sugar variations in normal and in sympathectomized dogs
نویسندگان
چکیده
منابع مشابه
comparison of blood flow velocity changes in posterior cerebral artery measured with transcranial doppler sonography in migraineurs with visual aura and normal persons after photostimulation
چکیده ندارد.
15 صفحه اولpatterns and variations in native and non-native interlanguage pragmatic rating: effects of rater training, intercultural proficiency, and self-assessment
although there are studies on pragmatic assessment, to date, literature has been almost silent about native and non-native english raters’ criteria for the assessment of efl learners’ pragmatic performance. focusing on this topic, this study pursued four purposes. the first one was to find criteria for rating the speech acts of apology and refusal in l2 by native and non-native english teachers...
15 صفحه اولVentricular function in cardiac-denervated and cardiac-sympathectomized conscious dogs.
The role of the autonomic nervous system in ventricular function was studied in conscious animals when either the cardiac nerves or the sympathetic nerves to the heart had been eliminated. Regional neural ablation was used to denervate the heart, and blockade of the cardiac sympathetic nerves was performed with propranolol. A reduction in the plateau of the ventricular output was seen in the ca...
متن کاملEffect of Acute Morphine Exposure on Insulin and Blood Sugar Levels in Normal Rats
OBJECTIVE: Social belief and experimental evidences indicate that opium and its alkaloids, morphine, produced hypoglycemic effects in animal models. This study was conducted in order to determine the role of morphine on blood glucose and insulin. MATERIAL AND METHODS: This is an empirical analysis investigating the laboratory albino male rats weighing 200-250 g. Rats in the control group recei...
متن کاملDiurnal variations of blood pressure in dogs.
Using the telemetry system, we measured the blood pressure (BP) invasively in seven adult mongrels while unanesthetized and unbound. Post-operative BP after implanting the telemetry BP transmitter showed temporarily high values due to the invasive nature of the surgery. It was, however, observed that BP gradually decreased thereafter, and showed settled trends from the eighth day post-operative...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Physiology
سال: 1939
ISSN: 0022-3751
DOI: 10.1113/jphysiol.1939.sp003740