Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement.
BACKGROUND There have been few reports studying the necessary interval between blood pressure measurements, after the initial rest period. METHODS Blood pressure was measured in 50 patients using the conventional oscillometric technique (COT) and the rapid oscillometric technique (ROT). RESULTS The difference between COT and ROT was -1.1 / -0.1 mmHg, which was not significantly different (p...
متن کاملBlood pressure measurement in adults: large cuffs for all?
STUDY OBJECTIVE The aim of the study was to determine whether a single size of cuff for adult blood pressure measurements is appropriate for general clinical practice. DESIGN The study was a prospective survey of a sample of adult blood pressure measurements using two cuffs with different bladder sizes (12 X 23 cm and 15 X 33 cm) in a randomised design using a random zero sphygmomanometer. ...
متن کاملValidation of TM-2655 oscillometric device for blood pressure measurement.
OBJECTIVE To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, systolic blood pressure range was 84-208 mmHg and diastolic blood pressure ran...
متن کاملEffect of Peripheral Edema on Oscillometric Blood Pressure Measurement
INTRODUCTION Blood pressure (BP) measurement is essential for epidemiological studies and clinical decisions. It seems that tissue characteristics can affect BP results and we try to find edema effect on BP results taken by different methods. METHODS BP of 55 children before open heart surgery were measured and compared according to three methods: Arterial as standard and reference, oscillome...
متن کاملOscillometric blood pressure measurement: the methodology, some observations, and suggestions.
Most noninvasive blood pressure (NIBP) devices use the oscillometric method. Published studies of oscillometric methodology introduced varied algorithmic approaches for determination of systolic (SBP), diastolic (DBP), and mean arterial (MAP) blood pressures. While there is a general agreement about MAP determination, controversy exists about the determination of SBP and DBP Accuracy of oscillo...