Blood glucose measurement by using hollow optical fiber-based attenuated total reflection probe.
A noninvasive glucose monitoring system based on mid-infrared, attenuated total reflection spectroscopy using a hollow optical fiber probe is developed. Owing to the flexible fiber probe, measurement of oral mucosa, where blood capillaries are near the skin surface, is possible. Blood glucose levels are measured by detecting the peak intensity of glucose absorption bands, and the experimental r...
متن کاملDetection of Ni2+ by a dimethylglyoxime probe using attenuated total-reflection infrared spectroscopy.
A new analytical approach for the detection of Ni2+ utilizing an attenuated total reflection (ATR) technique is discussed in this paper. Nickel detection was accomplished on a silicon ATR parallelogram crystal uniformly coated by a ca. 1.5-microm Nafion film embedded with dimethylglyoxime (DMG) probe molecules. The detection of Ni2+ is based on the appearance of a unique infrared absorption pea...
متن کاملPrecise Optical Fiber Length Measurement System Based on Fresnel Reflection
In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical reflected pulses are obtained from a single nanosecond pulse injected at the input due to the difference in lengths of the reference and test fibers. The lengths of the different op...
متن کاملNon-Invasive Determination of Blood Glucose Levels by Optical Waveguide
Objective: Today, there are various non-invasive techniques available for the determination of blood glucose levels. In this study, the level of blood glucose was determined by developing a new device using near-infrared (NIR) wavelength, glass optical waveguide, and the phenomenon of evanescent waves. Materials and Methods: The body's interstitial fluid has made possible the development of ne...
متن کاملSingle-reflection attenuated total reflection of organic monolayers on silicon.
Attenuated total re ection (ATR) spectroscopy, a wellknown surface technique, is frequently used for examining very thin lms on substrates. However, when it comes to examining thin lms on silicon substrates, the high refractive index of the substrates seems to preclude ATR analysis. This paper demonstrates that extraordinary sensitivity can be achieved by using ATR to analyze monolayers on...